Loop-Mediated Isothermal Amplification and Lateral Flow Immunochromatography Technology for Rapid Diagnosis of Influenza A/B
Diagnostics · 06.05.2024 · 14 (9) · 967
DOI: 10.3390/diagnostics14090967 ↗Kurz gefasst
Fachartikel in der Zeitschrift Diagnostics, online erschienen am 06.05.2024. Verfasst von Woong Sik Jang und 4 weiteren Autor:innen. Beteiligte Einrichtung: Emergency Medicine, College of Medicine, Korea University Guro Hospital, 148, Gurodong-ro, Guro-gu, Seoul 08308, Republic of Korea. Die Arbeit wurde bisher 13-mal zitiert (Crossref) und nennt 43 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: the Korea Health Industry Development Institute (KHIDI), funded by the Ministry of Health & Welfare, Republic of Korea, the National Research Foundation of Korea (NRF), funded by the Korean Government, MSIP, the Basic Science Research Program through the National Research Foundation of Korea (NRF) funded by the Ministry of Education.
Abstract (Originalsprache)
Influenza viruses cause highly contagious respiratory diseases that cause millions of deaths worldwide. Rapid detection of influenza viruses is essential for accurate diagnosis and the initiation of appropriate treatment. We developed a loop-mediated isothermal amplification and lateral flow assay (LAMP-LFA) capable of simultaneously detecting influenza A and influenza B. Primer sets for influenza A and influenza B were designed to target conserved regions of segment 7 and the nucleoprotein gene, respectively. Optimized through various primer set ratios, the assay operated at 62 °C for 30 min. For a total of 243 (85 influenza A positive, 58 influenza B positive and 100 negative) nasopharyngeal swab samples, the performance of the influenza A/B multiplex LAMP-LFA was compared with that of the commercial AllplexTM Respiratory Panel 1 assay (Seegene, Seoul, Korea). The influenza A/B multiplex LAMP-LFA demonstrated a specificity of 98% for the non-infected clinical samples, along with sensitivities of 94.1% for the influenza A clinical samples and 96.6% for the influenza B clinical samples, respectively. The influenza A/B multiplex LAMP-LFA showed high sensitivity and specificity, indicating that it is reliable for use in a low-resource environment.
Schlagwörter
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Emergency Medicine, College of Medicine, Korea University Guro Hospital, 148, Gurodong-ro, Guro-gu, Seoul 08308, Republic of Korea.
- BK21 Graduate Program, Department of Biomedical Sciences, College of Medicine, Korea University, 145 Anam-ro, Seongbuk-gu, Seoul 02841, Republic of Korea.
- Department of Laboratory Medicine, College of Medicine, Korea University Guro Hospital, 148, Gurodong-ro, Guro-gu, Seoul 08308, Republic of Korea.
ORCID-Profile: Woong Sik Jang, Chae Seung Lim
Förderung
- the Korea Health Industry Development Institute (KHIDI), funded by the Ministry of Health & Welfare, Republic of Korea
- the National Research Foundation of Korea (NRF), funded by the Korean Government, MSIP
- the Basic Science Research Program through the National Research Foundation of Korea (NRF) funded by the Ministry of Education
- Korea Health Industry Development Institute (KHIDI)
- Ministry of Health & Welfare of the Republic of Korea
- National Research Foundation of Korea (NRF), the Korean government’s MSIP
- Ministry of Education
Zitieren
APA
Jang, W. S., Lee, J. M., Lee, E., Park, S., & Lim, C. S. (2024). Loop-Mediated Isothermal Amplification and Lateral Flow Immunochromatography Technology for Rapid Diagnosis of Influenza A/B. Diagnostics, 14(9), 967. https://doi.org/10.3390/diagnostics14090967
Vancouver
Jang WS, Lee JM, Lee E, Park S, Lim CS. Loop-Mediated Isothermal Amplification and Lateral Flow Immunochromatography Technology for Rapid Diagnosis of Influenza A/B. Diagnostics. 2024;14(9):967. doi:10.3390/diagnostics14090967
BibTeX
@article{Jang2024,
author = {Jang, Woong Sik and Lee, Jun Min and Lee, Eunji and Park, Seoyeon and Lim, Chae Seung},
title = {Loop-Mediated Isothermal Amplification and Lateral Flow Immunochromatography Technology for Rapid Diagnosis of Influenza A/B},
journal = {Diagnostics},
year = {2024},
volume = {14},
number = {9},
pages = {967},
doi = {10.3390/diagnostics14090967}
}
EUVIMED