Human AI Teaming for Coronary CT Angiography Assessment: Impact on Imaging Workflow and Diagnostic Accuracy
Diagnostics · 30.11.2023 · 13 (23) · 3574
DOI: 10.3390/diagnostics13233574 ↗Kurz gefasst
Fachartikel in der Zeitschrift Diagnostics, online erschienen am 30.11.2023. Verfasst von Florian Andre und 12 weiteren Autor:innen. Beteiligte Einrichtung: Department of Cardiology, Angiology and Pneumology, University of Heidelberg, 69120 Heidelberg, Germany. Die Arbeit wurde bisher 19-mal zitiert (Crossref) und nennt 24 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Siemens Healthcare (Germany), Siemens Healthcare, Forchheim, Germany.
Abstract (Originalsprache)
As the number of coronary computed tomography angiography (CTA) examinations is expected to increase, technologies to optimize the imaging workflow are of great interest. The aim of this study was to investigate the potential of artificial intelligence (AI) to improve clinical workflow and diagnostic accuracy in high-volume cardiac imaging centers. A total of 120 patients (79 men; 62.4 (55.0–72.7) years; 26.7 (24.9–30.3) kg/m2) undergoing coronary CTA were randomly assigned to a standard or an AI-based (human AI) coronary analysis group. Severity of coronary artery disease was graded according to CAD-RADS. Initial reports were reviewed and changes were classified. Both groups were similar with regard to age, sex, body mass index, heart rate, Agatston score, and CAD-RADS. The time for coronary CTA assessment (142.5 (106.5–215.0) s vs. 195.0 (146.0–265.5) s; p < 0.002) and the total reporting time (274.0 (208.0–377.0) s vs. 350 (264.0–445.5) s; p < 0.02) were lower in the human AI than in the standard group. The number of cases with no, minor, or CAD-RADS relevant changes did not differ significantly between groups (52, 7, 1 vs. 50, 8, 2; p = 0.80). AI-based analysis significantly improves clinical workflow, even in a specialized high-volume setting, by reducing CTA analysis and overall reporting time without compromising diagnostic accuracy.
Schlagwörter
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Cardiology, Angiology and Pneumology, University of Heidelberg, 69120 Heidelberg, Germany.
- MVZ DRZ Heidelberg, 69126 Heidelberg, Germany.
- Siemens Healthineers, 91301 Forchheim, Germany.
- Siemens Healthineers, Princeton, NJ 08540, USA.
ORCID-Profile: Florian Andre, Matthias Aurich, Ann-Kathrin Jatsch, Michael Wels
Förderung
- Siemens Healthcare (Germany)
- Siemens Healthcare, Forchheim, Germany
Zitieren
APA
Andre, F., Fortner, P., Aurich, M., Seitz, S., Jatsch, A. K., Schöbinger, M., Wels, M., Kraus, M., Gülsün, M. A., Frey, N., Sommer, A., Görich, J., & Buss, S. J. (2023). Human AI Teaming for Coronary CT Angiography Assessment: Impact on Imaging Workflow and Diagnostic Accuracy. Diagnostics, 13(23), 3574. https://doi.org/10.3390/diagnostics13233574
Vancouver
Andre F, Fortner P, Aurich M, Seitz S, Jatsch AK, Schöbinger M, et al. Human AI Teaming for Coronary CT Angiography Assessment: Impact on Imaging Workflow and Diagnostic Accuracy. Diagnostics. 2023;13(23):3574. doi:10.3390/diagnostics13233574
BibTeX
@article{Andre2023,
author = {Andre, Florian and Fortner, Philipp and Aurich, Matthias and Seitz, Sebastian and Jatsch, Ann-Kathrin and Schöbinger, Max and Wels, Michael and Kraus, Martin and Gülsün, Mehmet Akif and Frey, Norbert and Sommer, Andre and Görich, Johannes and Buss, Sebastian J},
title = {Human AI Teaming for Coronary CT Angiography Assessment: Impact on Imaging Workflow and Diagnostic Accuracy},
journal = {Diagnostics},
year = {2023},
volume = {13},
number = {23},
pages = {3574},
doi = {10.3390/diagnostics13233574}
}
EUVIMED