EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Automatized Detection of Periodontal Bone Loss on Periapical Radiographs by Vision Transformer Networks

Helena Dujic iD, Ole Meyer, Patrick Hoss, Uta Christine Wölfle, Annika Wülk, Theresa Meusburger, Leon Meier, Volker Gruhn, Marc Hesenius, Reinhard Hickel, Jan Kühnisch iD

Diagnostics · 29.11.2023 · 13 (23) · 3562

DOI: 10.3390/diagnostics13233562 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Diagnostics, online erschienen am 29.11.2023. Verfasst von Helena Dujic und 10 weiteren Autor:innen. Beteiligte Einrichtung: Department of Conservative Dentistry and Periodontology, LMU University Hospital, LMU Munich, 80336 Munich, Germany. Die Arbeit wurde bisher 31-mal zitiert (Crossref) und nennt 52 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Several artificial intelligence-based models have been presented for the detection of periodontal bone loss (PBL), mostly using convolutional neural networks, which are the state of the art in deep learning. Given the emerging breakthrough of transformer networks in computer vision, we aimed to evaluate various models for automatized PBL detection. An image data set of 21,819 anonymized periapical radiographs from the upper/lower and anterior/posterior regions was assessed by calibrated dentists according to PBL. Five vision transformer networks (ViT-base/ViT-large from Google, BEiT-base/BEiT-large from Microsoft, DeiT-base from Facebook/Meta) were utilized and evaluated. Accuracy (ACC), sensitivity (SE), specificity (SP), positive/negative predictive value (PPV/NPV) and area under the ROC curve (AUC) were statistically determined. The overall diagnostic ACC and AUC values ranged from 83.4 to 85.2% and 0.899 to 0.918 for all evaluated transformer networks, respectively. Differences in diagnostic performance were evident for lower (ACC 94.1–96.7%; AUC 0.944–0.970) and upper anterior (86.7–90.2%; 0.948–0.958) and lower (85.6–87.2%; 0.913–0.937) and upper posterior teeth (78.1–81.0%; 0.851–0.875). In this study, only minor differences among the tested networks were detected for PBL detection. To increase the diagnostic performance and to support the clinical use of such networks, further optimisations with larger and manually annotated image data sets are needed.

Schlagwörter

Stichwörter der Autor:innen

artificial intelligencedeep learningdiagnosticsmachine learningperiapical radiographsperiodontal bone lossperiodontitistransformer

Autor:innen und Institutionen

  • Department of Conservative Dentistry and Periodontology, LMU University Hospital, LMU Munich, 80336 Munich, Germany.
  • Institute for Software Engineering, University of Duisburg-Essen, 45127 Essen, Germany.

ORCID-Profile: Helena Dujic, Jan Kühnisch

Zitieren

APA

Dujic, H., Meyer, O., Hoss, P., Wölfle, U. C., Wülk, A., Meusburger, T., Meier, L., Gruhn, V., Hesenius, M., Hickel, R., & Kühnisch, J. (2023). Automatized Detection of Periodontal Bone Loss on Periapical Radiographs by Vision Transformer Networks. Diagnostics, 13(23), 3562. https://doi.org/10.3390/diagnostics13233562

Vancouver

Dujic H, Meyer O, Hoss P, Wölfle UC, Wülk A, Meusburger T, et al. Automatized Detection of Periodontal Bone Loss on Periapical Radiographs by Vision Transformer Networks. Diagnostics. 2023;13(23):3562. doi:10.3390/diagnostics13233562

BibTeX
@article{Dujic2023,
  author = {Dujic, Helena and Meyer, Ole and Hoss, Patrick and Wölfle, Uta Christine and Wülk, Annika and Meusburger, Theresa and Meier, Leon and Gruhn, Volker and Hesenius, Marc and Hickel, Reinhard and Kühnisch, Jan},
  title = {Automatized Detection of Periodontal Bone Loss on Periapical Radiographs by Vision Transformer Networks},
  journal = {Diagnostics},
  year = {2023},
  volume = {13},
  number = {23},
  pages = {3562},
  doi = {10.3390/diagnostics13233562}
}
Kostenlos starten →