Multi-Layer Preprocessing and U-Net with Residual Attention Block for Retinal Blood Vessel Segmentation
Diagnostics · 01.11.2023 · 13 (21) · 3364
DOI: 10.3390/diagnostics13213364 ↗Kurz gefasst
Fachartikel in der Zeitschrift Diagnostics, online erschienen am 01.11.2023. Verfasst von Ahmed Alsayat und 5 weiteren Autor:innen. Beteiligte Einrichtung: Department of Computer Science, College of Computer and Information Sciences, Jouf University, Sakaka 72341, Saudi Arabia. Die Arbeit wurde bisher 16-mal zitiert (Crossref) und nennt 69 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Al Jouf University, The Deputyship of Research & Innovation, Ministry of Education in Saudi Arabia.
Abstract (Originalsprache)
Retinal blood vessel segmentation is a valuable tool for clinicians to diagnose conditions such as atherosclerosis, glaucoma, and age-related macular degeneration. This paper presents a new framework for segmenting blood vessels in retinal images. The framework has two stages: a multi-layer preprocessing stage and a subsequent segmentation stage employing a U-Net with a multi-residual attention block. The multi-layer preprocessing stage has three steps. The first step is noise reduction, employing a U-shaped convolutional neural network with matrix factorization (CNN with MF) and detailed U-shaped U-Net (D_U-Net) to minimize image noise, culminating in the selection of the most suitable image based on the PSNR and SSIM values. The second step is dynamic data imputation, utilizing multiple models for the purpose of filling in missing data. The third step is data augmentation through the utilization of a latent diffusion model (LDM) to expand the training dataset size. The second stage of the framework is segmentation, where the U-Nets with a multi-residual attention block are used to segment the retinal images after they have been preprocessed and noise has been removed. The experiments show that the framework is effective at segmenting retinal blood vessels. It achieved Dice scores of 95.32, accuracy of 93.56, precision of 95.68, and recall of 95.45. It also achieved efficient results in removing noise using CNN with matrix factorization (MF) and D-U-NET according to values of PSNR and SSIM for (0.1, 0.25, 0.5, and 0.75) levels of noise. The LDM achieved an inception score of 13.6 and an FID of 46.2 in the augmentation step.
Schlagwörter
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Computer Science, College of Computer and Information Sciences, Jouf University, Sakaka 72341, Saudi Arabia.
- Computer Science Division, Faculty of Science, Tanta University, Tanta 31527, Egypt.
- Computer Science Department, College of Computer Science and Engineering, Taibah University, Yanbu 966144, Saudi Arabia.
- Information Systems Department, College of Computer and Information Sciences, Jouf University, Sakaka 72341, Saudi Arabia.
- Computer Science Department, Faculty of Computers and Informatics, Zagazig University, Zagazig 44511, Egypt.
- Computer Science Department, College of Computer Science and Engineering, Taibah University, Medina 42353, Saudi Arabia.
ORCID-Profile: Ahmed Alsayat, Mahmoud Elmezain, Saad Alanazi, Ayman Mohamed Mostafa, Wael Said
Förderung
- Al Jouf University
- The Deputyship of Research & Innovation, Ministry of Education in Saudi Arabia
Zitieren
APA
Alsayat, A., Elmezain, M., Alanazi, S., Alruily, M., Mostafa, A. M., & Said, W. (2023). Multi-Layer Preprocessing and U-Net with Residual Attention Block for Retinal Blood Vessel Segmentation. Diagnostics, 13(21), 3364. https://doi.org/10.3390/diagnostics13213364
Vancouver
Alsayat A, Elmezain M, Alanazi S, Alruily M, Mostafa AM, Said W. Multi-Layer Preprocessing and U-Net with Residual Attention Block for Retinal Blood Vessel Segmentation. Diagnostics. 2023;13(21):3364. doi:10.3390/diagnostics13213364
BibTeX
@article{Alsayat2023,
author = {Alsayat, Ahmed and Elmezain, Mahmoud and Alanazi, Saad and Alruily, Meshrif and Mostafa, Ayman Mohamed and Said, Wael},
title = {Multi-Layer Preprocessing and U-Net with Residual Attention Block for Retinal Blood Vessel Segmentation},
journal = {Diagnostics},
year = {2023},
volume = {13},
number = {21},
pages = {3364},
doi = {10.3390/diagnostics13213364}
}
EUVIMED