EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Diagnostic Accuracy of ki-67 Labeling Index in Endoscopic Ultrasonography-Fine-Needle Aspiration Cytology and Biopsy of Pancreatic Neuroendocrine Neoplasms

Jung-Soo Pyo iD, Nae Yu Kim iD, Kyueng-Whan Min, Il Hwan Oh iD, Dae Hyun Lim iD, Byoung Kwan Son iD

Diagnostics · 25.08.2023 · 13 (17) · 2756

DOI: 10.3390/diagnostics13172756 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Diagnostics, online erschienen am 25.08.2023. Verfasst von Jung-Soo Pyo und 5 weiteren Autor:innen. Beteiligte Einrichtung: Department of Pathology, Uijeongbu Eulji Medical Center, Eulji University School of Medicine, Uijeongbu-si 11759, Gyeonggi-do, Republic of Korea. Die Arbeit wurde bisher 6-mal zitiert (Crossref) und nennt 30 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Background

This study aimed to compare the diagnostic accuracy of the Ki-67 labeling index (LI) between endoscopic ultrasonography-fine-needle aspiration cytology/biopsy (EUS-FNAC/FNB) and surgical specimens of pancreatic neuroendocrine neoplasms (PanNENs).

Methods

Conventional meta-analysis and diagnostic test accuracy (DTA) reviews were performed on 17 eligible studies. The DTA review involved calculating the sensitivity, specificity, diagnostic odds ratio (OR), and area under the curve (AUC) of the summary receiver operating characteristic (SROC) curve. In addition, subgroup analysis was conducted based on EUS-FNAC and FNB, tumor grade, and tumor size.

Results

The overall concordance rate of WHO grade based on Ki-67 LI between the EUS-FNAC/FNB and the surgical specimen was 0.767 (95% confidence interval (CI), 0.713–0.814). Concordance rates of the EUS-FNAC and EUS-FNB subgroups were 0.741 (95% CI, 0.681–0.794) and 0.839 (95% CI, 0.738–0.906), respectively. In the DTA review for grade 3, the sensitivity and specificity were calculated to be 0.786 (95% CI, 0.590–0.917) and 0.998 (95% CI, 0.987–1.000), respectively. The diagnostic OR and AUC of the SROC curve were 150.220 (95% CI, 46.145–489.000) and 0.983, respectively. The sensitivity and specificity were observed to be highest in the grade 1 and 3 subgroups, respectively.

Conclusions

Higher concordance of tumor grade based on Ki-67 LI was observed between EUS-FNAC/FNB and surgical specimens, indicating the potential usefulness of Ki-67 LI in predicting PanNEN tumor grade in EUS-FNAC/FNB.

Schlagwörter

Stichwörter der Autor:innen

Ki-67diagnostic test accuracy reviewendoscopic ultrasonographyfine needle aspiration cytology/biopsymeta-analysispancreatic neuroendocrine neoplasm

Autor:innen und Institutionen

  • Department of Pathology, Uijeongbu Eulji Medical Center, Eulji University School of Medicine, Uijeongbu-si 11759, Gyeonggi-do, Republic of Korea.
  • Department of Internal Medicine, Uijeongbu Eulji Medical Center, Eulji University School of Medicine, Uijeongbu-si 11759, Gyeonggi-do, Republic of Korea.

ORCID-Profile: Jung-Soo Pyo, Nae Yu Kim, Il Hwan Oh, Dae Hyun Lim, Byoung Kwan Son

Zitieren

APA

Pyo, J. S., Kim, N. Y., Min, K. W., Oh, I. H., Lim, D. H., & Son, B. K. (2023). Diagnostic Accuracy of ki-67 Labeling Index in Endoscopic Ultrasonography-Fine-Needle Aspiration Cytology and Biopsy of Pancreatic Neuroendocrine Neoplasms. Diagnostics, 13(17), 2756. https://doi.org/10.3390/diagnostics13172756

Vancouver

Pyo JS, Kim NY, Min KW, Oh IH, Lim DH, Son BK. Diagnostic Accuracy of ki-67 Labeling Index in Endoscopic Ultrasonography-Fine-Needle Aspiration Cytology and Biopsy of Pancreatic Neuroendocrine Neoplasms. Diagnostics. 2023;13(17):2756. doi:10.3390/diagnostics13172756

BibTeX
@article{Pyo2023,
  author = {Pyo, Jung-Soo and Kim, Nae Yu and Min, Kyueng-Whan and Oh, Il Hwan and Lim, Dae Hyun and Son, Byoung Kwan},
  title = {Diagnostic Accuracy of ki-67 Labeling Index in Endoscopic Ultrasonography-Fine-Needle Aspiration Cytology and Biopsy of Pancreatic Neuroendocrine Neoplasms},
  journal = {Diagnostics},
  year = {2023},
  volume = {13},
  number = {17},
  pages = {2756},
  doi = {10.3390/diagnostics13172756}
}
Kostenlos starten →