Left Ventricle Segmentation in Echocardiography with Transformer
Diagnostics · 13.07.2023 · 13 (14) · 2365
DOI: 10.3390/diagnostics13142365 ↗Kurz gefasst
Fachartikel in der Zeitschrift Diagnostics, online erschienen am 13.07.2023. Verfasst von Minqi Liao und 8 weiteren Autor:innen. Beteiligte Einrichtung: Department of Cardiology, Dongguan People's Hospital (The Tenth Affiliated Hospital of Southern Medical Univerity), No 78, Wandao Road, Wanjiang Dist…. Die Arbeit wurde bisher 34-mal zitiert (Crossref) und nennt 20 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).
Abstract (Originalsprache)
Left ventricular ejection fraction (LVEF) plays as an essential role in the assessment of cardiac function, providing quantitative data support for the medical diagnosis of heart disease. Robust evaluation of the ejection fraction relies on accurate left ventricular (LV) segmentation of echocardiograms. Because human bias and expensive labor cost exist in manual echocardiographic analysis, computer algorithms of deep-learning have been developed to help human experts in segmentation tasks. Most of the previous work is based on the convolutional neural networks (CNN) structure and has achieved good results. However, the region occupied by the left ventricle is large for echocardiography. Therefore, the limited receptive field of CNN leaves much room for improvement in the effectiveness of LV segmentation. In recent years, Vision Transformer models have demonstrated their effectiveness and universality in traditional semantic segmentation tasks. Inspired by this, we propose two models that use two different pure Transformers as the basic framework for LV segmentation in echocardiography: one combines Swin Transformer and K-Net, and the other uses Segformer. We evaluate these two models on the EchoNet-Dynamic dataset of LV segmentation and compare the quantitative metrics with other models for LV segmentation. The experimental results show that the mean Dice similarity of the two models scores are 92.92% and 92.79%, respectively, which outperform most of the previous mainstream CNN models. In addition, we found that for some samples that were not easily segmented, whereas both our models successfully recognized the valve region and separated left ventricle and left atrium, the CNN model segmented them together as a single part. Therefore, it becomes possible for us to obtain accurate segmentation results through simple post-processing, by filtering out the parts with the largest circumference or pixel square. These promising results prove the effectiveness of the two models and reveal the potential of Transformer structure in echocardiographic segmentation.
Schlagwörter
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Cardiology, Dongguan People's Hospital (The Tenth Affiliated Hospital of Southern Medical Univerity), No 78, Wandao Road, Wanjiang District, Dongguan 523059, China.
- National Space Science Center, Chinese Academy of Sciences, Beijing 100190, China.
- University of Chinese Academy of Sciences, Beijing 100049, China.
- National Astronomical Observatories, Chinese Academy of Sciences, Beijing 100101, China.
- Peng Cheng National Laboratory, Shenzhen 518000, China.
- Endocrinology Centre, Fuwai Hospital, Chinese Academy of Medical Sciences and Peking Union Medical College, Beijing 100037, China.
ORCID-Profile: Long Xu
Zitieren
APA
Liao, M., Lian, Y., Yao, Y., Chen, L., Gao, F., Xu, L., Huang, X., Feng, X., & Guo, S. (2023). Left Ventricle Segmentation in Echocardiography with Transformer. Diagnostics, 13(14), 2365. https://doi.org/10.3390/diagnostics13142365
Vancouver
Liao M, Lian Y, Yao Y, Chen L, Gao F, Xu L, et al. Left Ventricle Segmentation in Echocardiography with Transformer. Diagnostics. 2023;13(14):2365. doi:10.3390/diagnostics13142365
BibTeX
@article{Liao2023,
author = {Liao, Minqi and Lian, Yifan and Yao, Yongzhao and Chen, Lihua and Gao, Fei and Xu, Long and Huang, Xin and Feng, Xinxing and Guo, Suxia},
title = {Left Ventricle Segmentation in Echocardiography with Transformer},
journal = {Diagnostics},
year = {2023},
volume = {13},
number = {14},
pages = {2365},
doi = {10.3390/diagnostics13142365}
}
EUVIMED