EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Three-Dimensional Enlow’s Counterpart Analysis: Neutral Track

Antonino Peluso iD, Giulia Falone, Rossana Pipitone, Francesco Moscagiuri, Francesco Caroccia iD, Michele D'Attilio iD

Diagnostics · 11.07.2023 · 13 (14) · 2337

DOI: 10.3390/diagnostics13142337 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Diagnostics, online erschienen am 11.07.2023. Verfasst von Antonino Peluso und 5 weiteren Autor:innen. Beteiligte Einrichtung: Department of Innovative Technologies in Medicine & Dentistry, University "G. d'Annunzio" Chieti-Pescara, 66100 Chieti, Italy. Die Arbeit wurde bisher 2-mal zitiert (Crossref) und nennt 31 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

The aim of this study is to provide a novel method to perform Enlow’s neutral track analysis on cone-beam computed tomography (CBCT) images. Eighteen CBCT images of skeletal Class I (ANB = 2° ± 2°) subjects (12 males and 6 females, aged from 9 to 19 years) with no history of previous orthodontic treatment were selected. For each subject, 2D Enlow’s neutral track analysis was performed on lateral cephalograms extracted from CBCT images and 3D neutral track analysis was performed on CBCT images. A Student’s t-test did not show any statistically significant difference between the 2D and 3D measurements and therefore the method proposed by this study to realize the neutral track analysis on 3D images is valid and superimposable on that described by Enlow on lateral cephalograms. Further studies with a large sample and different skeletal class subjects are needed to confirm the results of this research.

Schlagwörter

Stichwörter der Autor:innen

anthropometrycephalometrycone-beam computed tomographydental diagnosisorthodonticsradiography

Autor:innen und Institutionen

  • Department of Innovative Technologies in Medicine & Dentistry, University "G. d'Annunzio" Chieti-Pescara, 66100 Chieti, Italy.

ORCID-Profile: Antonino Peluso, Francesco Caroccia, Michele D'Attilio

Zitieren

APA

Peluso, A., Falone, G., Pipitone, R., Moscagiuri, F., Caroccia, F., & D'Attilio, M. (2023). Three-Dimensional Enlow’s Counterpart Analysis: Neutral Track. Diagnostics, 13(14), 2337. https://doi.org/10.3390/diagnostics13142337

Vancouver

Peluso A, Falone G, Pipitone R, Moscagiuri F, Caroccia F, D'Attilio M. Three-Dimensional Enlow’s Counterpart Analysis: Neutral Track. Diagnostics. 2023;13(14):2337. doi:10.3390/diagnostics13142337

BibTeX
@article{Peluso2023,
  author = {Peluso, Antonino and Falone, Giulia and Pipitone, Rossana and Moscagiuri, Francesco and Caroccia, Francesco and D'Attilio, Michele},
  title = {Three-Dimensional Enlow’s Counterpart Analysis: Neutral Track},
  journal = {Diagnostics},
  year = {2023},
  volume = {13},
  number = {14},
  pages = {2337},
  doi = {10.3390/diagnostics13142337}
}
Kostenlos starten →