EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Enhanced Image Processing Using Complex Averaging in Diffusion-Weighted Imaging of the Prostate: The Impact on Image Quality and Lesion Detectability

Sebastian Werner, Dominik Zinsser, Michael Esser, Dominik Nickel iD, Konstantin Nikolaou iD, Ahmed E Othman iD

Diagnostics · 10.07.2023 · 13 (14) · 2325

DOI: 10.3390/diagnostics13142325 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Diagnostics, online erschienen am 10.07.2023. Verfasst von Sebastian Werner und 5 weiteren Autor:innen. Beteiligte Einrichtung: Department of Diagnostic and Interventional Radiology, Eberhard Karls University, Tuebingen University Hospital, 72076 Tuebingen, Germany. Die Arbeit wurde bisher 8-mal zitiert (Crossref) und nennt 21 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Diffusion-weighted images of the prostate can suffer from a “hazy” background in low signal-intensity areas. We hypothesize that enhanced image processing (EIP) using complex averaging reduces artifacts, noise, and distortion in conventionally acquired diffusion-weighted images and synthesized high b-value images, thus leading to higher image quality and better detection of potentially malignant lesions. Conventional DWI trace images with a b-value of 1000 s/mm2 (b1000), calculated images with a b-value of 2000 s/mm2 (cb2000), and ADC maps of 3T multiparametric prostate MRIs in 53 patients (age 68.8 ± 10 years) were retrospectively evaluated. Standard images were compared to images using EIP. In the standard images, 36 lesions were detected in the peripheral zone and 20 in the transition zone. In 13 patients, EIP led to the detection of 8 additional lesions and the upgrading of 6 lesions; 6 of these patients were diagnosed with prostate carcinoma Gleason 7 or 8. EIP improved qualitative ratings for overall image quality and lesion detectability. Artifacts were significantly reduced in the cb2000 images. Quantitative measurements for lesion detectability expressed as an SI ratio were significantly improved. EIP using complex averaging led to image quality improvements in acquired and synthesized DWI, potentially resulting in elevated diagnostic accuracy and management changes.

Schlagwörter

Stichwörter der Autor:innen

complex averagingdetectiondiffusion-weighted imaginghigh b-valueimage qualitymultiparametric MRIprostate cancer

Autor:innen und Institutionen

  • Department of Diagnostic and Interventional Radiology, Eberhard Karls University, Tuebingen University Hospital, 72076 Tuebingen, Germany.
  • MR Application Predevelopment, Siemens Healthineers, 91052 Erlangen, Germany.
  • Department of Neuroradiology, University Medical Center Mainz, 55131 Mainz, Germany.

ORCID-Profile: Dominik Nickel, Konstantin Nikolaou, Ahmed E Othman

Zitieren

APA

Werner, S., Zinsser, D., Esser, M., Nickel, D., Nikolaou, K., & Othman, A. E. (2023). Enhanced Image Processing Using Complex Averaging in Diffusion-Weighted Imaging of the Prostate: The Impact on Image Quality and Lesion Detectability. Diagnostics, 13(14), 2325. https://doi.org/10.3390/diagnostics13142325

Vancouver

Werner S, Zinsser D, Esser M, Nickel D, Nikolaou K, Othman AE. Enhanced Image Processing Using Complex Averaging in Diffusion-Weighted Imaging of the Prostate: The Impact on Image Quality and Lesion Detectability. Diagnostics. 2023;13(14):2325. doi:10.3390/diagnostics13142325

BibTeX
@article{Werner2023,
  author = {Werner, Sebastian and Zinsser, Dominik and Esser, Michael and Nickel, Dominik and Nikolaou, Konstantin and Othman, Ahmed E},
  title = {Enhanced Image Processing Using Complex Averaging in Diffusion-Weighted Imaging of the Prostate: The Impact on Image Quality and Lesion Detectability},
  journal = {Diagnostics},
  year = {2023},
  volume = {13},
  number = {14},
  pages = {2325},
  doi = {10.3390/diagnostics13142325}
}
Kostenlos starten →