Automated Opportunistic Trabecular Volumetric Bone Mineral Density Extraction Outperforms Manual Measurements for the Prediction of Vertebral Fractures in Routine CT
Diagnostics · 20.06.2023 · 13 (12) · 2119
DOI: 10.3390/diagnostics13122119 ↗Kurz gefasst
Fachartikel in der Zeitschrift Diagnostics, online erschienen am 20.06.2023. Verfasst von Sophia S Goller und 11 weiteren Autor:innen. Beteiligte Einrichtung: Department of Radiology, University Hospital, LMU Munich, Marchioninistr. 15, 81377 Munich, Germany. Die Arbeit wurde bisher 7-mal zitiert (Crossref) und nennt 55 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: German Society of Musculoskeletal Radiology (DGMSR), Munich Clinician Scientist Program (MCSP), German Research Foundation (Deutsche Forschunsggemeinschaft, DFG).
Abstract (Originalsprache)
Opportunistic osteoporosis screening using multidetector CT-scans (MDCT) and convolutional neural network (CNN)-derived segmentations of the spine to generate volumetric bone mineral density (vBMD) bears the potential to improve incidental osteoporotic vertebral fracture (VF) prediction. However, the performance compared to the established manual opportunistic vBMD measures remains unclear. Hence, we investigated patients with a routine MDCT of the spine who had developed a new osteoporotic incidental VF and frequency matched to patients without incidental VFs as assessed on follow-up MDCT images after 1.5 years. Automated vBMD was generated using CNN-generated segmentation masks and asynchronous calibration. Additionally, manual vBMD was sampled by two radiologists. Automated vBMD measurements in patients with incidental VFs at 1.5-years follow-up (n = 53) were significantly lower compared to patients without incidental VFs (n = 104) (83.6 ± 29.4 mg/cm3 vs. 102.1 ± 27.7 mg/cm3, p < 0.001). This comparison was not significant for manually assessed vBMD (99.2 ± 37.6 mg/cm3 vs. 107.9 ± 33.9 mg/cm3, p = 0.30). When adjusting for age and sex, both automated and manual vBMD measurements were significantly associated with incidental VFs at 1.5-year follow-up, however, the associations were stronger for automated measurements (β = −0.32; 95% confidence interval (CI): −20.10, 4.35; p < 0.001) compared to manual measurements (β = −0.15; 95% CI: −11.16, 5.16; p < 0.03). In conclusion, automated opportunistic measurements are feasible and can be useful for bone mineral density assessment in clinical routine.
Schlagwörter
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Radiology, University Hospital, LMU Munich, Marchioninistr. 15, 81377 Munich, Germany.
- Institute for Diagnostic and Interventional Neuroradiology, University Hospital, LMU Munich, Marchioninistr. 15, 81377 Munich, Germany.
- Department of Neurosurgery, University Hospital, LMU Munich, Marchioninistr. 15, 81377 Munich, Germany.
- Institute of Micro Technology and Medical Device Technology (MIMED), Technical University of Munich, Boltzmannstr. 15, 85748 Garching, Germany.
- Department of Diagnostic and Interventional Neuroradiology, Klinikum Rechts der Isar, Technical University of Munich, Ismaninger Str. 22, 81675 Munich, Germany.
- Department of Diagnostic and Interventional Radiology, Klinikum Rechts der Isar, Technical University of Munich, Ismaninger Str. 22, 81675 Munich, Germany.
ORCID-Profile: Sophia S Goller, Jon F Rischewski, Sebastian Siller, Vanessa F Schmidt, Robert Stahl, Thomas Baum, Jan S Kirschke, Sarah C Foreman
Förderung
- German Society of Musculoskeletal Radiology (DGMSR)
- Munich Clinician Scientist Program (MCSP)
- German Research Foundation (Deutsche Forschunsggemeinschaft, DFG)
- Munich Clinician Scientist Program (MCSP) of the University of Munich
- European Research Council (ERC)
Zitieren
APA
Goller, S. S., Rischewski, J. F., Liebig, T., Ricke, J., Siller, S., Schmidt, V. F., Stahl, R., Kulozik, J., Baum, T., Kirschke, J. S., Foreman, S. C., & Gersing, A. S. (2023). Automated Opportunistic Trabecular Volumetric Bone Mineral Density Extraction Outperforms Manual Measurements for the Prediction of Vertebral Fractures in Routine CT. Diagnostics, 13(12), 2119. https://doi.org/10.3390/diagnostics13122119
Vancouver
Goller SS, Rischewski JF, Liebig T, Ricke J, Siller S, Schmidt VF, et al. Automated Opportunistic Trabecular Volumetric Bone Mineral Density Extraction Outperforms Manual Measurements for the Prediction of Vertebral Fractures in Routine CT. Diagnostics. 2023;13(12):2119. doi:10.3390/diagnostics13122119
BibTeX
@article{Goller2023,
author = {Goller, Sophia S and Rischewski, Jon F and Liebig, Thomas and Ricke, Jens and Siller, Sebastian and Schmidt, Vanessa F and Stahl, Robert and Kulozik, Julian and Baum, Thomas and Kirschke, Jan S and Foreman, Sarah C and Gersing, Alexandra S},
title = {Automated Opportunistic Trabecular Volumetric Bone Mineral Density Extraction Outperforms Manual Measurements for the Prediction of Vertebral Fractures in Routine CT},
journal = {Diagnostics},
year = {2023},
volume = {13},
number = {12},
pages = {2119},
doi = {10.3390/diagnostics13122119}
}
EUVIMED