Assessment of Image Quality of Coronary CT Angiography Using Deep Learning-Based CT Reconstruction: Phantom and Patient Studies
Diagnostics · 26.05.2023 · 13 (11) · 1862
DOI: 10.3390/diagnostics13111862 ↗Kurz gefasst
Fachartikel in der Zeitschrift Diagnostics, online erschienen am 26.05.2023. Verfasst von Pil-Hyun Jeon und 9 weiteren Autor:innen. Beteiligte Einrichtung: Department of Radiology, Wonju Severance Christian Hospital, Wonju 26426, Republic of Korea. Die Arbeit wurde bisher 6-mal zitiert (Crossref) und nennt 30 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Institute of Information & Communications Technology Planning & Evaluation and Electronics and Telecommunications Research Institute, IITP (Institute of Information & Communications Technology Planning & Evaluation), Electronics and Telecommunications Research Institute (ETRI)’s internal funds.
Abstract (Originalsprache)
Background
In coronary computed tomography angiography (CCTA), the main issue of image quality is noise in obese patients, blooming artifacts due to calcium and stents, high-risk coronary plaques, and radiation exposure to patients.
Objective
To compare the CCTA image quality of deep learning-based reconstruction (DLR) with that of filtered back projection (FBP) and iterative reconstruction (IR).
Methods
This was a phantom study of 90 patients who underwent CCTA. CCTA images were acquired using FBP, IR, and DLR. In the phantom study, the aortic root and the left main coronary artery in the chest phantom were simulated using a needleless syringe. The patients were classified into three groups according to their body mass index. Noise, the signal-to-noise ratio (SNR), and the contrast-to-noise ratio (CNR) were measured for image quantification. A subjective analysis was also performed for FBP, IR, and DLR.
Results
According to the phantom study, DLR reduced noise by 59.8% compared to FBP and increased SNR and CNR by 121.4% and 123.6%, respectively. In a patient study, DLR reduced noise compared to FBP and IR. Furthermore, DLR increased the SNR and CNR more than FBP and IR. In terms of subjective scores, DLR was higher than FBP and IR.
Conclusion
In both phantom and patient studies, DLR effectively reduced image noise and improved SNR and CNR. Therefore, the DLR may be useful for CCTA examinations.
Schlagwörter
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Radiology, Wonju Severance Christian Hospital, Wonju 26426, Republic of Korea.
- Medical Imaging AI Research Center, Canon Medical System, Seoul 08826, Republic of Korea.
- Department of Radiology, Seoul National University College of Medicine, Seoul 03080, Republic of Korea.
- Medical Information Research Section, Electronics and Telecommunications Research Institute, Daejeon 34129, Republic of Korea.
- Department of Radiological Science, Eulji University, Seongnam 13135, Republic of Korea.
- Department of Bigdata Medical Convergence, Eulji University, Seongnam 13135, Republic of Korea.
ORCID-Profile: Chuluunbaatar Otgonbaatar, Kihong Son, Myung-Ae Chung
Förderung
- Institute of Information & Communications Technology Planning & Evaluation and Electronics and Telecommunications Research Institute
- IITP (Institute of Information & Communications Technology Planning & Evaluation)
- Electronics and Telecommunications Research Institute (ETRI)’s internal funds
Zitieren
APA
Jeon, P. H., Jeon, S. H., Ko, D., An, G., Shim, H., Otgonbaatar, C., Son, K., Kim, D., Ko, S. M., & Chung, M. A. (2023). Assessment of Image Quality of Coronary CT Angiography Using Deep Learning-Based CT Reconstruction: Phantom and Patient Studies. Diagnostics, 13(11), 1862. https://doi.org/10.3390/diagnostics13111862
Vancouver
Jeon PH, Jeon SH, Ko D, An G, Shim H, Otgonbaatar C, et al. Assessment of Image Quality of Coronary CT Angiography Using Deep Learning-Based CT Reconstruction: Phantom and Patient Studies. Diagnostics. 2023;13(11):1862. doi:10.3390/diagnostics13111862
BibTeX
@article{Jeon2023,
author = {Jeon, Pil-Hyun and Jeon, Sang-Hyun and Ko, Donghee and An, Giyong and Shim, Hackjoon and Otgonbaatar, Chuluunbaatar and Son, Kihong and Kim, Daehong and Ko, Sung Min and Chung, Myung-Ae},
title = {Assessment of Image Quality of Coronary CT Angiography Using Deep Learning-Based CT Reconstruction: Phantom and Patient Studies},
journal = {Diagnostics},
year = {2023},
volume = {13},
number = {11},
pages = {1862},
doi = {10.3390/diagnostics13111862}
}
EUVIMED