Noise Reduction Using Singular Value Decomposition with Jensen–Shannon Divergence for Coronary Computed Tomography Angiography
Diagnostics · 15.03.2023 · 13 (6) · 1111
DOI: 10.3390/diagnostics13061111 ↗Kurz gefasst
Fachartikel in der Zeitschrift Diagnostics, online erschienen am 15.03.2023. Verfasst von Ryosuke Kasai und 1 weiteren Autor:innen. Beteiligte Einrichtung: Department of Medical Imaging/Nuclear Medicine, Institute of Biomedical Sciences, Tokushima University, 3-18-15 Kuramoto, Tokushima 770-8509, Japan. Die Arbeit wurde bisher 3-mal zitiert (Crossref) und nennt 34 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).
Abstract (Originalsprache)
Coronary computed tomography angiography (CCTA) is widely used due to its improvements in computed tomography (CT) diagnostic performance. Unlike other CT examinations, CCTA requires shorter rotation times of the X-ray tube, improving the temporal resolution and facilitating the imaging of the beating heart in a stationary state. However, reconstructed CT images, including those of the coronary arteries, contain insufficient X-ray photons and considerable noise. In this study, we introduce an image-processing technique for noise reduction using singular value decomposition (SVD) for CCTA images. The threshold of SVD was determined on the basis of minimization of Jensen–Shannon (JS) divergence. Experiments were performed with various numerical phantoms and varying levels of noise to reduce noise in clinical CCTA images using the determined threshold value. The numerical phantoms produced 10% higher-quality images than the conventional noise reduction method when compared on a quantitative SSIM basis. The threshold value determined by minimizing the JS–divergence was found to be useful for efficient noise reduction in actual clinical images, depending on the level of noise.
Schlagwörter
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Medical Imaging/Nuclear Medicine, Institute of Biomedical Sciences, Tokushima University, 3-18-15 Kuramoto, Tokushima 770-8509, Japan.
ORCID-Profile: Ryosuke Kasai, Hideki Otsuka
Zitieren
APA
Kasai, R., & Otsuka, H. (2023). Noise Reduction Using Singular Value Decomposition with Jensen–Shannon Divergence for Coronary Computed Tomography Angiography. Diagnostics, 13(6), 1111. https://doi.org/10.3390/diagnostics13061111
Vancouver
Kasai R, Otsuka H. Noise Reduction Using Singular Value Decomposition with Jensen–Shannon Divergence for Coronary Computed Tomography Angiography. Diagnostics. 2023;13(6):1111. doi:10.3390/diagnostics13061111
BibTeX
@article{Kasai2023,
author = {Kasai, Ryosuke and Otsuka, Hideki},
title = {Noise Reduction Using Singular Value Decomposition with Jensen–Shannon Divergence for Coronary Computed Tomography Angiography},
journal = {Diagnostics},
year = {2023},
volume = {13},
number = {6},
pages = {1111},
doi = {10.3390/diagnostics13061111}
}
EUVIMED