EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

AI: Can It Make a Difference to the Predictive Value of Ultrasound Breast Biopsy?

Jean L Browne, Maria Ángela Pascual iD, Jorge Perez, Sulimar Salazar, Beatriz Valero iD, Ignacio Rodriguez iD, Darío Cassina, Juan Luis Alcázar iD, Stefano Guerriero iD, Betlem Graupera iD

Diagnostics · 20.02.2023 · 13 (4) · 811

DOI: 10.3390/diagnostics13040811 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Diagnostics, online erschienen am 20.02.2023. Verfasst von Jean L Browne und 9 weiteren Autor:innen. Beteiligte Einrichtung: Department of Obstetrics, Gynecology, and Reproduction, Hospital Universitari Dexeus, 08028 Barcelona, Spain. Die Arbeit wurde bisher 21-mal zitiert (Crossref) und nennt 22 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

(1)

Background

This study aims to compare the ground truth (pathology results) against the BI-RADS classification of images acquired while performing breast ultrasound diagnostic examinations that led to a biopsy and against the result of processing the same images through the AI algorithm KOIOS DS TM (KOIOS). (2)

Methods

All results of biopsies performed with ultrasound guidance during 2019 were recovered from the pathology department. Readers selected the image which better represented the BI-RADS classification, confirmed correlation to the biopsied image, and submitted it to the KOIOS AI software. The results of the BI-RADS classification of the diagnostic study performed at our institution were set against the KOIOS classification and both were compared to the pathology reports. (3)

Results

403 cases were included in this study. Pathology rendered 197 malignant and 206 benign reports. Four biopsies on BI-RADS 0 and two images are included. Of fifty BI-RADS 3 cases biopsied, only seven rendered cancers. All but one had a positive or suspicious cytology; all were classified as suspicious by KOIOS. Using KOIOS, 17 B3 biopsies could have been avoided. Of 347 BI-RADS 4, 5, and 6 cases, 190 were malignant (54.7%). Because only KOIOS suspicious and probably malignant categories should be biopsied, 312 biopsies would have resulted in 187 malignant lesions (60%), but 10 cancers would have been missed. (4)

Conclusions

KOIOS had a higher ratio of positive biopsies in this selected case study vis-à-vis the BI-RADS 4, 5 and 6 categories. A large number of biopsies in the BI-RADS 3 category could have been avoided.

Schlagwörter

Stichwörter der Autor:innen

artificial intelligencebreast biopsybreast cancerbreast ultrasoundcomputer-aided diagnosis

Autor:innen und Institutionen

  • Department of Obstetrics, Gynecology, and Reproduction, Hospital Universitari Dexeus, 08028 Barcelona, Spain.
  • Department of Obstetrics and Gynecology, Clínica Universidad de Navarra, 31008 Pamplona, Spain.
  • Department of Obstetrics and Gynecology, University of Cagliari, 09042 Cagliari, Italy.

ORCID-Profile: Maria Ángela Pascual, Beatriz Valero, Ignacio Rodriguez, Juan Luis Alcázar, Stefano Guerriero, Betlem Graupera

Zitieren

APA

Browne, J. L., Pascual, M. Á., Perez, J., Salazar, S., Valero, B., Rodriguez, I., Cassina, D., Alcázar, J. L., Guerriero, S., & Graupera, B. (2023). AI: Can It Make a Difference to the Predictive Value of Ultrasound Breast Biopsy?. Diagnostics, 13(4), 811. https://doi.org/10.3390/diagnostics13040811

Vancouver

Browne JL, Pascual MÁ, Perez J, Salazar S, Valero B, Rodriguez I, et al. AI: Can It Make a Difference to the Predictive Value of Ultrasound Breast Biopsy?. Diagnostics. 2023;13(4):811. doi:10.3390/diagnostics13040811

BibTeX
@article{Browne2023,
  author = {Browne, Jean L and Pascual, Maria Ángela and Perez, Jorge and Salazar, Sulimar and Valero, Beatriz and Rodriguez, Ignacio and Cassina, Darío and Alcázar, Juan Luis and Guerriero, Stefano and Graupera, Betlem},
  title = {AI: Can It Make a Difference to the Predictive Value of Ultrasound Breast Biopsy?},
  journal = {Diagnostics},
  year = {2023},
  volume = {13},
  number = {4},
  pages = {811},
  doi = {10.3390/diagnostics13040811}
}
Kostenlos starten →