EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Graphene Oxide–PAMAM Nanocomposite and Ionic Liquid Modified Carbon Paste Electrode: An Efficient Electrochemical Sensor for Simultaneous Determination of Catechol and Resorcinol

Fariba Garkani Nejad, Hadi Beitollahi iD, Iran Sheikhshoaie

Diagnostics · 08.02.2023 · 13 (4) · 632

DOI: 10.3390/diagnostics13040632 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Diagnostics, online erschienen am 08.02.2023. Verfasst von Fariba Garkani Nejad und 2 weiteren Autor:innen. Beteiligte Einrichtung: Department of Chemistry, Faculty of Science, Shahid Bahonar University of Kerman, Kerman 7616914111, Iran. Die Arbeit wurde bisher 35-mal zitiert (Crossref) und nennt 49 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

In this paper, a simple strategy was proposed for the analysis of catechol by a carbon paste electrode (CPE) modified with graphene oxide–third generation of poly(amidoamine) dendrimer (GO/G3–PAMAM) nanocomposite and ionic liquid (IL). The synthesis of GO–PAMAM nanocomposite was confirmed using X-ray diffraction (XRD), energy-dispersive X-ray spectroscopy (EDS), field emission scanning electron microscopy (FE-SEM), and Fourier transform infrared spectroscopy (FT-IR) techniques. The prepared modified electrode (GO–PAMAM/ILCPE) exhibited good performance to detect catechol with a notable decrease in overpotential and increase in current compared with an unmodified CPE. Under optimum experimental conditions, GO–PAMAM/ILCPE electrochemical sensors indicated a lower limit of detection (LOD) of 0.034 μM and a linear response in the concentration range of 0.1 to 200.0 µM for the quantitative measurement of catechol in aqueous solutions. In addition, GO–PAMAM/ILCPE sensor exhibited an ability to simultaneously determine catechol and resorcinol. It can be found that catechol and resorcinol could be completely separated on the GO–PAMAM/ILCPE with the differential pulse voltammetry (DPV) technique. Finally, a GO–PAMAM/ILCPE sensor was utilized to detect catechol and resorcinol in water samples with recoveries of 96.2% to 103.3% and relative standard deviations (RSDs) of less than 1.7%.

Schlagwörter

Stichwörter der Autor:innen

carbon paste electrodecatecholelectrochemical sensorgraphene oxide–poly(amidoamine) dendrimer nanocompositeionic liquidresorcinol

Autor:innen und Institutionen

  • Department of Chemistry, Faculty of Science, Shahid Bahonar University of Kerman, Kerman 7616914111, Iran.
  • Environment Department, Institute of Science and High Technology and Environmental Sciences, Graduate University of Advanced Technology, Kerman 7631818356, Iran.

ORCID-Profile: Hadi Beitollahi

Zitieren

APA

Garkani Nejad, F., Beitollahi, H., & Sheikhshoaie, I. (2023). Graphene Oxide–PAMAM Nanocomposite and Ionic Liquid Modified Carbon Paste Electrode: An Efficient Electrochemical Sensor for Simultaneous Determination of Catechol and Resorcinol. Diagnostics, 13(4), 632. https://doi.org/10.3390/diagnostics13040632

Vancouver

Garkani Nejad F, Beitollahi H, Sheikhshoaie I. Graphene Oxide–PAMAM Nanocomposite and Ionic Liquid Modified Carbon Paste Electrode: An Efficient Electrochemical Sensor for Simultaneous Determination of Catechol and Resorcinol. Diagnostics. 2023;13(4):632. doi:10.3390/diagnostics13040632

BibTeX
@article{GarkaniNejad2023,
  author = {Garkani Nejad, Fariba and Beitollahi, Hadi and Sheikhshoaie, Iran},
  title = {Graphene Oxide–PAMAM Nanocomposite and Ionic Liquid Modified Carbon Paste Electrode: An Efficient Electrochemical Sensor for Simultaneous Determination of Catechol and Resorcinol},
  journal = {Diagnostics},
  year = {2023},
  volume = {13},
  number = {4},
  pages = {632},
  doi = {10.3390/diagnostics13040632}
}
Kostenlos starten →