EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

VIS-NIR Diffuse Reflectance Spectroscopy System with Self-Calibrating Fiber-Optic Probe: Study of Perturbation Resistance

Valeriya Perekatova, Alexey Kostyuk, Mikhail Kirillin iD, Ekaterina Sergeeva, Daria Kurakina iD, Olga Shemagina iD, Anna Orlova, Aleksandr Khilov iD, Ilya Turchin iD

Diagnostics · 26.01.2023 · 13 (3) · 457

DOI: 10.3390/diagnostics13030457 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Diagnostics, online erschienen am 26.01.2023. Verfasst von Valeriya Perekatova und 8 weiteren Autor:innen. Beteiligte Einrichtung: Institute of Applied Physics RAS, 603950 Nizhny Novgorod, Russia. Die Arbeit wurde bisher 18-mal zitiert (Crossref) und nennt 49 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Center of Excellence «Center of Photonics» funded by The Ministry of Science and Higher Education of the Russian Federation, Center of Excellence «Center of Photonics», The Ministry of Science and Higher Education of the Russian Federation.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

We report on the comparative analysis of self-calibrating and single-slope diffuse reflectance spectroscopy in resistance to different measurement perturbations. We developed an experimental setup for diffuse reflectance spectroscopy (DRS) in a wide VIS-NIR range with a fiber-optic probe equipped with two source and two detection fibers capable of providing measurements employing both single- and dual-slope (self-calibrating) approaches. In order to fit the dynamic range of a spectrometer in the wavelength range of 460–1030 nm, different exposure times have been applied for short (2 mm) and long (4 mm) source-detector distances. The stability of the self-calibrating and traditional single-slope approaches to instrumental perturbations were compared in phantom and in vivo studies on human palm, including attenuations in individual channels, fiber curving, and introducing optical inhomogeneities in the probe–tissue interface. The self-calibrating approach demonstrated high resistance to instrumental perturbations introduced in the source and detection channels, while the single-slope approach showed resistance only to perturbations introduced into the source channels.

Schlagwörter

Stichwörter der Autor:innen

diffuse optical spectroscopydiffuse reflectance spectroscopydiffuse scatteringoxygenationratiometric approachself-calibrating approachtissue chromophorestissue optics

Autor:innen und Institutionen

  • Institute of Applied Physics RAS, 603950 Nizhny Novgorod, Russia.

ORCID-Profile: Mikhail Kirillin, Daria Kurakina, Olga Shemagina, Aleksandr Khilov, Ilya Turchin

Förderung

  • Center of Excellence «Center of Photonics» funded by The Ministry of Science and Higher Education of the Russian Federation
  • Center of Excellence «Center of Photonics»
  • The Ministry of Science and Higher Education of the Russian Federation

Zitieren

APA

Perekatova, V., Kostyuk, A., Kirillin, M., Sergeeva, E., Kurakina, D., Shemagina, O., Orlova, A., Khilov, A., & Turchin, I. (2023). VIS-NIR Diffuse Reflectance Spectroscopy System with Self-Calibrating Fiber-Optic Probe: Study of Perturbation Resistance. Diagnostics, 13(3), 457. https://doi.org/10.3390/diagnostics13030457

Vancouver

Perekatova V, Kostyuk A, Kirillin M, Sergeeva E, Kurakina D, Shemagina O, et al. VIS-NIR Diffuse Reflectance Spectroscopy System with Self-Calibrating Fiber-Optic Probe: Study of Perturbation Resistance. Diagnostics. 2023;13(3):457. doi:10.3390/diagnostics13030457

BibTeX
@article{Perekatova2023,
  author = {Perekatova, Valeriya and Kostyuk, Alexey and Kirillin, Mikhail and Sergeeva, Ekaterina and Kurakina, Daria and Shemagina, Olga and Orlova, Anna and Khilov, Aleksandr and Turchin, Ilya},
  title = {VIS-NIR Diffuse Reflectance Spectroscopy System with Self-Calibrating Fiber-Optic Probe: Study of Perturbation Resistance},
  journal = {Diagnostics},
  year = {2023},
  volume = {13},
  number = {3},
  pages = {457},
  doi = {10.3390/diagnostics13030457}
}
Kostenlos starten →