Novel Detector Configurations in Cone-Beam CT Systems: A Simulation Study
Crystals · 29.04.2024 · 14 (5) · 416
DOI: 10.3390/cryst14050416 ↗Kurz gefasst
Fachartikel in der Zeitschrift Crystals, online erschienen am 29.04.2024. Verfasst von Evangelia Karali und 4 weiteren Autor:innen. Die Arbeit wurde bisher 5-mal zitiert (Crossref) und nennt 48 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).
Abstract (Originalsprache)
Cone-beam computed tomography (CBCT) has emerged in recent years as an adequate alternative to mammography and tomosynthesis due to the several advantages over traditional mammography, including its ability to provide 3D images, its reduced radiation dose, and its ability to image dense breasts more effectively and conduct more effective breast compressions, etc. Furthermore, CBCT is capable of providing images with high sensitivity and specificity, allowing a more accurate evaluation, even of dense breasts, where mammography and tomosynthesis may lead to a false diagnosis. Clinical and experimental CBCT systems rely on cesium iodine (CsI:Tl) scintillators for X-ray energy conversion. This study comprises an investigation among different novel CBCT detector technologies, consisting either of scintillators (BGO, LSO:Ce, LYSO:Ce, LuAG:Ce, CaF2:Eu, LaBr3:Ce) or semiconductors (Silicon, CZT) in order to define the optimum detector design for a future experimental setup, dedicated to breast imaging. For this purpose, a micro-CBCT system was adapted, using GATE v9.2.1, consisting of the aforementioned various detection schemes. Two phantom configurations were selected: (a) an aluminum capillary positioned at the center of the field of view in order to calculate the system’s spatial resolution and (b) a breast phantom consisting of spheres of different materials, such that their characteristics are close to the breast composition. Breast phantom contrast-to-noise ratios (CNRs) were extracted from the phantom’s tomographic images. The images were reconstructed with filtered back projection (FBP) and ordered subsets expectation-maximization (OSEM) algorithms. The semiconductors acted satisfactorily in low-density matter, while LYSO:Ce, LaBr3:Ce, and LuAG:Ce presented adequate CNRs for all the different spheres’ densities. The energy converters that are presented in this study were evaluated for their performance against the standard CsI:Tl crystal.
Zitieren
APA
Karali, E., Michail, C., Fountos, G., Kalyvas, N., & Valais, I. (2024). Novel Detector Configurations in Cone-Beam CT Systems: A Simulation Study. Crystals, 14(5), 416. https://doi.org/10.3390/cryst14050416
Vancouver
Karali E, Michail C, Fountos G, Kalyvas N, Valais I. Novel Detector Configurations in Cone-Beam CT Systems: A Simulation Study. Crystals. 2024;14(5):416. doi:10.3390/cryst14050416
BibTeX
@article{Karali2024,
author = {Karali, Evangelia and Michail, Christos and Fountos, George and Kalyvas, Nektarios and Valais, Ioannis},
title = {Novel Detector Configurations in Cone-Beam CT Systems: A Simulation Study},
journal = {Crystals},
year = {2024},
volume = {14},
number = {5},
pages = {416},
doi = {10.3390/cryst14050416}
}
EUVIMED