Numerical Simulation Research on Thermoacoustic Instability of Cryogenic Hydrogen Filling Pipeline

Qidong Zhang, Yuan Ma, Fushou Xie, Liqiang Ai, Shengbao Wu, Yanzhong Li

Cryo · 2025

DOI: 10.3390/cryo1030009 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Cryo, 2025. Verfasst von Qidong Zhang und 5 weiteren Autor:innen. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 18 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: National Natural Science Foundation of China Special Project, National Natural Science Foundation of China.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

This article uses FLUENT to construct a two-dimensional axisymmetric numerical model of a cryogenic hydrogen charging pipeline. By loading with initial temperature gradient and transient initial pressure disturbance, the basic characteristics of low-temperature hydrogen Taconis thermoacoustic oscillation are calculated, including temperature, heat flux density distribution, pressure amplitude, and frequency. The instability boundary of hydrogen TAO is also obtained. The results show that (1) the temperature distribution and flow characteristics of the gas inside the pipeline exhibit significant periodic changes. In the first half of the oscillation period, the cold-end gas moves towards the end of the pipeline. Low-viscosity cold hydrogen is easily heated and rapidly expands. In the second half of the cycle, the expanding cold gas pushes the hot-end gas to move towards the cold end, forming a low-pressure zone and causing gas backflow. (2) Thermoacoustic oscillation can also cause additional thermal leakage on the pipeline wall. The average heat flux during one cycle is 1150.1 W/m2 for inflow and 1087.7 W/m2 for outflow, with a net inflow heat flux of 62.4 W/m2. (3) The instability boundary of the system is mainly determined by the temperature ratio of the cold and hot ends α, temperature gradient β, and length ratio of the cold and hot ends ξ. Increasing the pipe diameter and minimizing the pipe length can effectively weaken the amplitude of thermoacoustic oscillations. This study provides theoretical support for predicting thermoacoustic oscillations in low-temperature hydrogen transport pipeline systems and offers insights for system stability control and design verification.

Förderung

  • National Natural Science Foundation of China Special Project
  • National Natural Science Foundation of China

Zitieren

APA

Zhang, Q., Ma, Y., Xie, F., Ai, L., Wu, S., & Li, Y. (2025). Numerical Simulation Research on Thermoacoustic Instability of Cryogenic Hydrogen Filling Pipeline. Cryo. https://doi.org/10.3390/cryo1030009

Vancouver

Zhang Q, Ma Y, Xie F, Ai L, Wu S, Li Y. Numerical Simulation Research on Thermoacoustic Instability of Cryogenic Hydrogen Filling Pipeline. Cryo. 2025. doi:10.3390/cryo1030009

BibTeX
@article{Zhang2025,
  author = {Zhang, Qidong and Ma, Yuan and Xie, Fushou and Ai, Liqiang and Wu, Shengbao and Li, Yanzhong},
  title = {Numerical Simulation Research on Thermoacoustic Instability of Cryogenic Hydrogen Filling Pipeline},
  journal = {Cryo},
  year = {2025},
  doi = {10.3390/cryo1030009}
}
Kostenlos starten →