EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Performance Evaluation of Instrument-Based SARS-CoV-2 Rapid Antigen Fluorescent Immunoassays for Point-of-Care Detection

Vidya Keshav, Lesley Scott, Lucia Hans, Wendy Stevens

COVID · 30.04.2026 · 6 (5) · 78

DOI: 10.3390/covid6050078 ↗

Kurz gefasst

Fachartikel in der Zeitschrift COVID, online erschienen am 30.04.2026. Verfasst von Vidya Keshav und 3 weiteren Autor:innen. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 28 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Gates Foundation.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Rapid antigen tests targeting SARS-CoV-2 nucleocapsid protein were essential for decentralised testing during the COVID-19 pandemic. Independent performance evaluations are essential to support regulatory approval and inform clinical implementation, particularly in resource-limited settings. This study presents a retrospective analytical and operational evaluation of two instrument-based fluorescent immunoassays (FIAs): the PCL COVID-19 Ag Rapid FIA and LumiraDx SARS-CoV-2 Ag Test. Analytical sensitivity was determined using recombinant nucleocapsid protein and viral cultures. Clinical performance was assessed using residual clinical specimens (n = 110) with RT-PCR as a reference, stratified by cycle threshold (Ct). Operational characteristics were assessed using a structured Likert framework. Overall sensitivity was 63% (51–73) for PCL and 95% (88–99) for LumiraDx. For Ct ≤ 25, sensitivity increased to 93% and 100%. Specificity was ≥97% for both. LumiraDx maintained sensitivity (83–94%) at Ct 25–30, whereas PCL did not detect any positives in this range. The limit of detection was 39 pM (PCL) and 0.6 pM (LumiraDx). Operational usability was high for both (90% PCL, 87% LumiraDx). LumiraDx showed higher analytical sensitivity across a broader viral load range, supporting primary diagnostic use, whereas PCL was limited to high viral loads. This evaluation provides a reproducible framework for rapid diagnostic assessment during emerging outbreaks.

Förderung

  • Gates Foundation

Zitieren

APA

Keshav, V., Scott, L., Hans, L., & Stevens, W. (2026). Performance Evaluation of Instrument-Based SARS-CoV-2 Rapid Antigen Fluorescent Immunoassays for Point-of-Care Detection. COVID, 6(5), 78. https://doi.org/10.3390/covid6050078

Vancouver

Keshav V, Scott L, Hans L, Stevens W. Performance Evaluation of Instrument-Based SARS-CoV-2 Rapid Antigen Fluorescent Immunoassays for Point-of-Care Detection. COVID. 2026;6(5):78. doi:10.3390/covid6050078

BibTeX
@article{Keshav2026,
  author = {Keshav, Vidya and Scott, Lesley and Hans, Lucia and Stevens, Wendy},
  title = {Performance Evaluation of Instrument-Based SARS-CoV-2 Rapid Antigen Fluorescent Immunoassays for Point-of-Care Detection},
  journal = {COVID},
  year = {2026},
  volume = {6},
  number = {5},
  pages = {78},
  doi = {10.3390/covid6050078}
}
Kostenlos starten →