EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

CadTool: An End-to-End Semiconductor Detector Simulation Tool

Hugo Allaire, José Ferreira Sousa, David Baudin, Miho Katsuragawa, Rémy Le Breton, Olivier Limousin, Aline Meuris, Tadayuki Takahashi, Shin’ichiro Takeda, Abel Vanel, Shin Watanabe

Condensed Matter · 10.11.2026 · 11 (4) · 43

DOI: 10.3390/condmat11040043 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Condensed Matter, online erschienen am 10.11.2026. Verfasst von Hugo Allaire und 10 weiteren Autor:innen. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Academie Spatiale d'Ile-de-France.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

CdTe and CdZnTe (CZT) sensors have attracted significant attention over the past 25 years as room-temperature semiconductor detectors for hard X-ray and γ-ray detection, with applications in astrophysics, medical imaging, non-destructive testing, and nuclear security. Their appeal lies in the combination of compact form factor, high stopping power, wide bandgap and favourable charge-transport properties. We present CadTool, an end-to-end simulation tool that combines GATE 10/Geant4 for photon transport and energy deposition with the SolidStateDetectors.jl library for electric-field calculation, charge transport and signal induction, followed by a modular electronics-readout model that produces digitized data in the same format as the corresponding experimental detector. We compare simulations with measurements from three CdTe detector configurations, simulated with a single set of charge-transport parameters: a 1 mm thick pixel detector and 1–2 mm thick double-sided strip detectors, all with a 250 µm pitch, under 241Am illumination, and a 2 mm thick pixel detector with an 800 µm pitch irradiated with 133Ba and 137Cs up to 662 keV. For the pixel detector and the 1 mm strip detector, the measured and simulated energy spectra below 70 keV differ by 7–12 % of their events, and the dominant one- and two-electrode multiplicity classes agree within 20%. At 662 keV, the inter-pixel charge loss agrees within their respective uncertainties, the mean cluster size within 1.2% and the multiplicity fractions within 1.73%. CadTool is intended to support the design and optimisation of future detector and Application Specific Integrated Circuit (ASIC) systems, provide detailed detector-response models for larger-scale simulations, generate synthetic datasets, and improve the understanding of charge-transport and signal-formation processes in semiconductor detectors.

Förderung

  • Academie Spatiale d'Ile-de-France

Zitieren

APA

Allaire, H., Sousa, J. F., Baudin, D., Katsuragawa, M., Breton, R. L., Limousin, O., Meuris, A., Takahashi, T., Takeda, S., Vanel, A., & Watanabe, S. (2026). CadTool: An End-to-End Semiconductor Detector Simulation Tool. Condensed Matter, 11(4), 43. https://doi.org/10.3390/condmat11040043

Vancouver

Allaire H, Sousa JF, Baudin D, Katsuragawa M, Breton RL, Limousin O, et al. CadTool: An End-to-End Semiconductor Detector Simulation Tool. Condensed Matter. 2026;11(4):43. doi:10.3390/condmat11040043

BibTeX
@article{Allaire2026,
  author = {Allaire, Hugo and Sousa, José Ferreira and Baudin, David and Katsuragawa, Miho and Breton, Rémy Le and Limousin, Olivier and Meuris, Aline and Takahashi, Tadayuki and Takeda, Shin’ichiro and Vanel, Abel and Watanabe, Shin},
  title = {CadTool: An End-to-End Semiconductor Detector Simulation Tool},
  journal = {Condensed Matter},
  year = {2026},
  volume = {11},
  number = {4},
  pages = {43},
  doi = {10.3390/condmat11040043}
}
Kostenlos starten →