EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Preload Attenuation Behavior of Bolted Joint Structures Under Transverse Vibration

Kaixuan Zhang, Ziwei Li, Xiaohan Lu, Yilong Liu, Yuqing Liu, Shengyu Zhao, Ming Guo, Shengao Wang

Coatings · 03.11.2026 · 16 (11) · 1307

DOI: 10.3390/coatings16111307 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Coatings, online erschienen am 03.11.2026. Verfasst von Kaixuan Zhang und 7 weiteren Autor:innen. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Bolt self-loosening under transverse vibration is governed by frictional contact and accumulated interfacial slip. In this study, transverse vibration tests were performed on M8 bolted joints under different initial preloads, displacement amplitudes, and excitation frequencies, with three tests per condition. Preload histories were analyzed using an operational four-stage framework comprising an initial abrupt decrease, lower-rate attenuation, a sustained acceleration interval, and a decelerating tail. N2 denotes the operationally identified onset of sustained acceleration, rather than an instantaneous physical discontinuity. Stage-II/III rate contrasts vary between conditions and are modest for several 0.3 mm cases. A model with an independently estimated N2 was favored over the specified alternative with acceleration starting at N1, subject to the comparison assumptions and conditional uncertainty analysis. Quantitative comparisons use repeat-test statistics normalized to each test’s own initial preload. At 5 Hz and 0.3 mm, the mean cycle counts to 50% preload are 206.20 ± 25.35 and 116.25 ± 17.75 cycles for nominal initial preloads of 10 and 12 kN, respectively. At 10 kN and 5 Hz, reducing amplitude from 0.3 to 0.2 mm increases this milestone to 922.25 ± 97.15 cycles. For nominal 12 kN and 0.3 mm, the values at 5, 7 and 10 Hz are 116.25 ± 17.75, 137.34 ± 17.36 and 267.70 ± 32.00 cycles, respectively. Values are means ± sample SDs. In the illustrated records, an independently identifiable later acceleration interval was not observed within 1110 cycles at 15 kN (Group 5) or within 1405 cycles at 0.1 mm (Group 7). The finite element model reproduces the overall staged form but shows substantial transition-time mismatch and is used to interpret representative contact-state evolution. The four-stage framework is a conditional description of the tested histories; it does not establish universally discrete mechanisms or a stage sequence applicable to every condition.

Zitieren

APA

Zhang, K., Li, Z., Lu, X., Liu, Y., Liu, Y., Zhao, S., Guo, M., & Wang, S. (2026). Preload Attenuation Behavior of Bolted Joint Structures Under Transverse Vibration. Coatings, 16(11), 1307. https://doi.org/10.3390/coatings16111307

Vancouver

Zhang K, Li Z, Lu X, Liu Y, Liu Y, Zhao S, et al. Preload Attenuation Behavior of Bolted Joint Structures Under Transverse Vibration. Coatings. 2026;16(11):1307. doi:10.3390/coatings16111307

BibTeX
@article{Zhang2026,
  author = {Zhang, Kaixuan and Li, Ziwei and Lu, Xiaohan and Liu, Yilong and Liu, Yuqing and Zhao, Shengyu and Guo, Ming and Wang, Shengao},
  title = {Preload Attenuation Behavior of Bolted Joint Structures Under Transverse Vibration},
  journal = {Coatings},
  year = {2026},
  volume = {16},
  number = {11},
  pages = {1307},
  doi = {10.3390/coatings16111307}
}
Kostenlos starten →