EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Hot-Dip Galvanized Steel in Fire: Linking NIR/MIR Reflection to Early-Stage Heating Delay Under Standard Fire Exposure

Lukasz Radosinski, Iwona Gajecka, Michał Chmiel, Aleksandra Porebska

Coatings · 30.10.2026 · 16 (11) · 1292

DOI: 10.3390/coatings16111292 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Coatings, online erschienen am 30.10.2026. Verfasst von Lukasz Radosinski und 3 weiteren Autor:innen. Die Arbeit nennt 17 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Hot-dip galvanizing (HDG) protects steel against corrosion, but its influence on heating during fire exposure remains uncertain. This study combines reference-normalized FTIR measurements for five surface conditions with indicative furnace tests for four conditions on HEA 200 steel elements under the EN 1363-1 heating regime. The time to reach 500 °C increased from 570 s for bare steel to 634 s for top-coated HDG, 727 s for polished steel and 773 s for intact HDG. These trends are consistent with reduced radiative absorption by reflective surfaces, while convection continues to supply heat. A section-factor-matched lumped model describes this behaviour through an energy balance combining convective heat transfer and Stefan–Boltzmann radiation. Sensitivity analysis shows that assuming constant low emissivity overpredicts heating delay relative to scenarios in which emissivity increases during exposure. Despite similar initial reflected signals, intact HDG and polished steel exhibited different heating. Thus, from a fire-design perspective, the variability of HDG surface conditions and the resulting uncertainty in its radiative properties may make it difficult to treat galvanized steel as having sufficiently repeatable physical for use in fire safety engineering design or for classification as a certified passive fire-protection system.

Zitieren

APA

Radosinski, L., Gajecka, I., Chmiel, M., & Porebska, A. (2026). Hot-Dip Galvanized Steel in Fire: Linking NIR/MIR Reflection to Early-Stage Heating Delay Under Standard Fire Exposure. Coatings, 16(11), 1292. https://doi.org/10.3390/coatings16111292

Vancouver

Radosinski L, Gajecka I, Chmiel M, Porebska A. Hot-Dip Galvanized Steel in Fire: Linking NIR/MIR Reflection to Early-Stage Heating Delay Under Standard Fire Exposure. Coatings. 2026;16(11):1292. doi:10.3390/coatings16111292

BibTeX
@article{Radosinski2026,
  author = {Radosinski, Lukasz and Gajecka, Iwona and Chmiel, Michał and Porebska, Aleksandra},
  title = {Hot-Dip Galvanized Steel in Fire: Linking NIR/MIR Reflection to Early-Stage Heating Delay Under Standard Fire Exposure},
  journal = {Coatings},
  year = {2026},
  volume = {16},
  number = {11},
  pages = {1292},
  doi = {10.3390/coatings16111292}
}