Study on the Bearing Performance and Influencing Parameters of Variable Cross-Section Cement–Soil Pipe Piles
Coatings · 23.04.2026 · 16 (5) · 515
DOI: 10.3390/coatings16050515 ↗Kurz gefasst
Fachartikel in der Zeitschrift Coatings, online erschienen am 23.04.2026. Verfasst von Xiaokang Wei und 6 weiteren Autor:innen. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Open Foundation of National Engineering Research Center of High-speed Railway Construction Technology, National Natural Science Foundation of China.
Abstract (Originalsprache)
Variable cross-section cement–soil pipe piles are an innovative soft ground improvement technology. They are tubular, special-shaped cement–soil mixing piles characterized by a tapered profile along the pile shaft (larger diameter at the top and smaller at the bottom) and an internal soil core. They offer advantages including reduced material consumption, lower engineering cost, and shorter construction duration. However, the systematic theoretical understanding of their bearing performance remains insufficient. In this study, the bearing mechanism and influencing parameters of variable cross-section pipe piles were systematically investigated via full-scale field tests, numerical simulations, and laboratory model tests. An exponential decay constitutive model considering the strain-softening behavior of cement–soil was developed and implemented through secondary development in the ABAQUS platform for parametric analysis. Laboratory model tests were further conducted to advance the understanding of the bearing mechanism of variable cross-section pipe piles. The results show that the ultimate bearing capacity of the proposed variable cross-section cement–soil pipe pile is approximately 189% higher than that of the conventional ones. The expanded outer diameter and expanded height are the dominant factors affecting the bearing capacity, while the inner diameter and pile length have a comparatively minimal influence: increasing the expanded outer diameter from 0.6 m to 1.2 m and the expanded height from 0 m to 5 m increased the ultimate bearing capacity from 445 kN to 868 kN and 936 kN, respectively. The effective pile length is determined to be 6 m, and the recommended minimum wall thickness of the pipe pile is 1/4 of the inner diameter. Laboratory tests further demonstrated an abrupt change in axial force at the variable section. The findings provide reliable theoretical support for the engineering design and field application of cement–soil variable cross-section pipe piles.
Förderung
- Open Foundation of National Engineering Research Center of High-speed Railway Construction Technology
- National Natural Science Foundation of China
Zitieren
APA
Wei, X., Zhou, C., Xin, G., Yin, Y., Li, C., Wang, S., & Zhu, J. (2026). Study on the Bearing Performance and Influencing Parameters of Variable Cross-Section Cement–Soil Pipe Piles. Coatings, 16(5), 515. https://doi.org/10.3390/coatings16050515
Vancouver
Wei X, Zhou C, Xin G, Yin Y, Li C, Wang S, et al. Study on the Bearing Performance and Influencing Parameters of Variable Cross-Section Cement–Soil Pipe Piles. Coatings. 2026;16(5):515. doi:10.3390/coatings16050515
BibTeX
@article{Wei2026,
author = {Wei, Xiaokang and Zhou, Chong and Xin, Gongfeng and Yin, Yongsheng and Li, Chao and Wang, Shuai and Zhu, Jianrui},
title = {Study on the Bearing Performance and Influencing Parameters of Variable Cross-Section Cement–Soil Pipe Piles},
journal = {Coatings},
year = {2026},
volume = {16},
number = {5},
pages = {515},
doi = {10.3390/coatings16050515}
}
EUVIMED