Optimising Patient Safety During the Use of Intraoperative Imaging for the Surgical Management of Facial Fractures: A Pilot Study
Craniomaxillofacial Trauma & Reconstruction · 25.05.2026 · 19 (2) · 26
DOI: 10.3390/cmtr19020026 ↗Kurz gefasst
Fachartikel in der Zeitschrift Craniomaxillofacial Trauma & Reconstruction, online erschienen am 25.05.2026. Verfasst von Nicole Garcia und 4 weiteren Autor:innen. Beteiligte Einrichtung: Department of Plastic and Reconstructive Surgery, Eastern Health, Melbourne, VIC 3128, Australia. Die Arbeit nennt 30 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).
Themen: Patientensicherheit
Abstract (Originalsprache)
The use of intraoperative computerised tomography (CT) to aid surgical management of facial fractures obviates the need for postoperative surgical scans, decreases return to theatre rates, and subsequently decreases overall hospital stay. This allows for better appreciation of a complex operative landscape in almost real time, and may become the gold standard of treatment. As with radiological investigations, decreasing radiation exposure of patients is a key goal. The aim of this study was to examine the effective radiation doses in patients undergoing surgical management of their facial fractures with the aid of a fixed-arm CT. This retrospective study was conducted on patients who underwent surgical fixation of their facial fractures within a hybrid surgical suite equipped with a fixed-arm cone beam CT (CBCT) from July 2023 to November 2024. The CBCT was used to assess adequacy of bony fixation. Data from imaging was collected to assess total effective radiation dose. Data from 30 random patients who underwent standard CT facial bones (CTFB) were collected as control. Data from 24 patients was collected. The majority were male (17/24, 70.8%) with an age range of 20–94 years. The average dose of the effective doses calculated in the CTFB cohort was 0.64 mSv (SD 0.05). This is a more-than-twenty-five-fold reduction in the average effective dose in the CBCT cohort, which was 0.025 mSv (SD 0.01). There was a statistically significant difference between the two cohorts with p < 0.0001 (95% CI 0.60–0.64). This study demonstrates that intraoperative CBCT delivers a significantly lower effective dose to patients compared with postoperative CTFB. Where facilities exist, CBCT offers a safer and more efficient alternative, with future work needed to assess staff dose, wait times, and cost impacts.
Schlagwörter
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Plastic and Reconstructive Surgery, Eastern Health, Melbourne, VIC 3128, Australia.
- Monash Health Imaging, Monash Health, Melbourne, VIC 3168, Australia.
- Department of Medical Imaging and Radiation Sciences, Monash University, Melbourne, VIC 3800, Australia.
- Department of Medical Imaging, Eastern Health, Melbourne, VIC 3128, Australia.
- Department of Surgery, Monash University, Melbourne, VIC 3128, Australia.
ORCID-Profile: Mohamed Badawy
Zitieren
APA
Garcia, N., Badawy, M., DiPasquale, J., Maciburko, S., & Seifman, M. (2026). Optimising Patient Safety During the Use of Intraoperative Imaging for the Surgical Management of Facial Fractures: A Pilot Study. Craniomaxillofacial Trauma & Reconstruction, 19(2), 26. https://doi.org/10.3390/cmtr19020026
Vancouver
Garcia N, Badawy M, DiPasquale J, Maciburko S, Seifman M. Optimising Patient Safety During the Use of Intraoperative Imaging for the Surgical Management of Facial Fractures: A Pilot Study. Craniomaxillofacial Trauma & Reconstruction. 2026;19(2):26. doi:10.3390/cmtr19020026
BibTeX
@article{Garcia2026,
author = {Garcia, Nicole and Badawy, Mohamed and DiPasquale, Jake and Maciburko, Simon and Seifman, Marc},
title = {Optimising Patient Safety During the Use of Intraoperative Imaging for the Surgical Management of Facial Fractures: A Pilot Study},
journal = {Craniomaxillofacial Trauma & Reconstruction},
year = {2026},
volume = {19},
number = {2},
pages = {26},
doi = {10.3390/cmtr19020026}
}