Evaluation of the Influence of a Disinfectant on Corrosion Protection Provided by Trivalent Chromium in AA2024-T3 Clad
Corrosion and Materials Degradation · 19.11.2026 · 7 (4) · 81
DOI: 10.3390/cmd7040081 ↗Kurz gefasst
Fachartikel in der Zeitschrift Corrosion and Materials Degradation, online erschienen am 19.11.2026. Verfasst von Carla Sofia Proença und 8 weiteren Autor:innen. Die Arbeit nennt 27 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: EDA.
Abstract (Originalsprache)
This study assessed the influence of an aircraft disinfectant containing peracetic acid, hydrogen peroxide and glycerol on the corrosion protection provided by the trivalent chromium conversion coating PreCoat A32 on AA2024-T3 clad aluminium. The investigation combined laboratory testing with an 18-month in-service evaluation of coated and painted components installed on Portuguese Air Force Epsilon TB-30 aircraft. Sporicidal assays demonstrated effective inactivation of Bacillus atrophaeus ( B. atrophaeus) spores on surfaces with and without PreCoat A32. Material compatibility was investigated using electrochemical impedance spectroscopy, microscopy, neutral salt spray and cyclic corrosion tests, together with visual inspection, eddy current testing, electrical conductivity measurements and X-ray computed tomography. Under the electrochemical test conditions, disinfectant exposure did not substantially accelerate the loss of protection provided by PreCoat A32. Climatic chamber testing emphasised the importance of the paint system in limiting pitting, while unpainted specimens remained susceptible to localised corrosion. During flight testing, PreCoat A32 and the hexavalent chromium reference treatment, Alodine 1201, showed comparable performance when combined with paint. No significant corrosion initiation or propagation was detected, and repeated disinfection produced no measurable conductivity change attributable to substrate degradation. These findings support the potential of PreCoat A32 as an alternative to Alodine 1201 within the tested painted systems, without a measurable adverse effect from disinfection under the operational conditions investigated.
Förderung
- EDA
Zitieren
APA
Proença, C. S., Reis, D., Santos, B., Tavares, M., Taoufiq, A., Nardeli, J. V., Barros, T., Antunes, W., & Cabral, A. (2026). Evaluation of the Influence of a Disinfectant on Corrosion Protection Provided by Trivalent Chromium in AA2024-T3 Clad. Corrosion and Materials Degradation, 7(4), 81. https://doi.org/10.3390/cmd7040081
Vancouver
Proença CS, Reis D, Santos B, Tavares M, Taoufiq A, Nardeli JV, et al. Evaluation of the Influence of a Disinfectant on Corrosion Protection Provided by Trivalent Chromium in AA2024-T3 Clad. Corrosion and Materials Degradation. 2026;7(4):81. doi:10.3390/cmd7040081
BibTeX
@article{Proena2026,
author = {Proença, Carla Sofia and Reis, Diego and Santos, Bruno and Tavares, Magda and Taoufiq, Amin and Nardeli, Jéssica V. and Barros, Tomás and Antunes, Wilson and Cabral, Ana},
title = {Evaluation of the Influence of a Disinfectant on Corrosion Protection Provided by Trivalent Chromium in AA2024-T3 Clad},
journal = {Corrosion and Materials Degradation},
year = {2026},
volume = {7},
number = {4},
pages = {81},
doi = {10.3390/cmd7040081}
}
EUVIMED