An Experimental Study on the Cathodic Protection Criteria of the 100 mV Depolarization for Chloride-Loaded Reinforced Concrete

Muhammad Akbar Caronge, Shunsuke Otani, Daisuke Yamamoto, Hidenori Hamada, Muhammad Wihardi Tjaronge

Corrosion and Materials Degradation · 20.08.2026 · 7 (3) · 52

DOI: 10.3390/cmd7030052 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Corrosion and Materials Degradation, online erschienen am 20.08.2026. Verfasst von Muhammad Akbar Caronge und 4 weiteren Autor:innen. Die Arbeit nennt 39 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

The 100 mV depolarization value cathodic protection (CP) criterion is widely used to protect the steel bars in atmospherically exposed concrete structures. The CP on the steel in concrete creates a secondary effect by increasing OH- ions and decreasing Cl- ions near the surface of the steel, against steel corrosion. In this phenomenon, there is a possibility that the CP criteria of 100 mV could be decreased due to the environmental changes caused by these secondary effects. In this study, the effects of different depolarization values of 25, 50, and 100 mV for the protection of steel bars in concrete specimens with different chloride ion concentrations were experimentally evaluated, and their effects on the corrosion rate of steel were investigated. The concrete had a water-to-cement ratio of 0.55 and a sand-to-total-aggregate ratio of 49%, and chloride was admixed as NaCl to give Cl− contents of 2, 5 and 10 kg/m3, equivalent to 0.58%, 1.45%, and 2.90% by mass of cement. The steel bars were pre-corroded by an impressed current of 1.33 A/m2 and were then protected for 250 days at 20 ± 2 °C and 60% relative humidity, the protection current being adjusted to hold average depolarization values of 21–37 mV, 57–63 mV, and 117–121 mV. After 250 days, the corrosion rate under CP was 0.18–0.95 mA/m2, a reduction of 60–77% relative to the unprotected specimens, and raising the target depolarization from 25 mV to 100 mV improved that reduction by only 6–11 percentage points. The measured reduction factor of 2.5–4.3 is far below the factor of 50 predicted by the Tafel relationship for a 100 mV activation polarization, which is attributed to the partly passive state of the steel and to the non-activation components of the 24 h potential decay. Within the exposure conditions tested, a depolarization criterion below 100 mV therefore protected the steel as effectively as the conventional 100 mV criterion while requiring a markedly lower protection current density.

Zitieren

APA

Caronge, M. A., Otani, S., Yamamoto, D., Hamada, H., & Tjaronge, M. W. (2026). An Experimental Study on the Cathodic Protection Criteria of the 100 mV Depolarization for Chloride-Loaded Reinforced Concrete. Corrosion and Materials Degradation, 7(3), 52. https://doi.org/10.3390/cmd7030052

Vancouver

Caronge MA, Otani S, Yamamoto D, Hamada H, Tjaronge MW. An Experimental Study on the Cathodic Protection Criteria of the 100 mV Depolarization for Chloride-Loaded Reinforced Concrete. Corrosion and Materials Degradation. 2026;7(3):52. doi:10.3390/cmd7030052

BibTeX
@article{Caronge2026,
  author = {Caronge, Muhammad Akbar and Otani, Shunsuke and Yamamoto, Daisuke and Hamada, Hidenori and Tjaronge, Muhammad Wihardi},
  title = {An Experimental Study on the Cathodic Protection Criteria of the 100 mV Depolarization for Chloride-Loaded Reinforced Concrete},
  journal = {Corrosion and Materials Degradation},
  year = {2026},
  volume = {7},
  number = {3},
  pages = {52},
  doi = {10.3390/cmd7030052}
}
Kostenlos starten →