Country-Specific Battery Sizing for Intraday Wind and Solar Shifting Across European Power Systems, 2015–2025
Clean Technologies · 19.11.2026 · 8 (6) · 195
DOI: 10.3390/cleantechnol8060195 ↗Kurz gefasst
Fachartikel in der Zeitschrift Clean Technologies, online erschienen am 19.11.2026. Verfasst von Maksym Mykhei und 5 weiteren Autor:innen. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Cultural and Educational Grant Agency of the Ministry of Education, Research, Development and Youth of the Slovak Republic, the Scientific Grant Agency of the Ministry of Education, Research, Development and Youth of the Slovak Republic and the Slovak Academy of Sciences, the Cultural and Educational Grant Agency of the Ministry of Education, Research, Development and Youth of the Slovak Republic.
Abstract (Originalsprache)
Reliable comparisons of battery storage requirements depend on an explicitly defined flexibility service. We applied a common hourly residual-load shifting rule to 25 European power systems during 2015–2025 (2,409,740 complete country–hours), using daily cyclic state-of-charge accounting, 90% round-trip efficiency, a 90% usable SOC range and independent P99 energy and power sizing. In 2025, nameplate energy spanned 1.28–142.17 GWh, power 0.28–23.36 GW and implied duration 4.43–7.38 h. Median energy relative to mean national load increased from 1.11 h in 2015 to 2.24 h in 2025. VRE penetration showed a positive country- and year-adjusted association with normalized energy (0.042 h per percentage point; country-clustered 95% confidence interval, 0.025–0.059), without supporting causal inference. In a matched temporal-service comparison, 2025 median energy was 2.240 h for the daily specification versus 5.027 h for the weekly specification; the contrast also reflects balancing and aggregation differences. With fixed P99 ratings, continuous SOC replay fully served a median 82.74% of days, compared with 98.08% marginal daily-envelope coverage. These are conditional technical benchmarks, not guaranteed service levels, observed curtailment recovery, economically optimal investments or total national storage requirements.
Förderung
- Cultural and Educational Grant Agency of the Ministry of Education, Research, Development and Youth of the Slovak Republic
- the Scientific Grant Agency of the Ministry of Education, Research, Development and Youth of the Slovak Republic and the Slovak Academy of Sciences
- the Cultural and Educational Grant Agency of the Ministry of Education, Research, Development and Youth of the Slovak Republic
Zitieren
APA
Mykhei, M., Taušová, M., Tauš, P., Čulková, K., Mudarri, T., & Alkhalaf, I. (2026). Country-Specific Battery Sizing for Intraday Wind and Solar Shifting Across European Power Systems, 2015–2025. Clean Technologies, 8(6), 195. https://doi.org/10.3390/cleantechnol8060195
Vancouver
Mykhei M, Taušová M, Tauš P, Čulková K, Mudarri T, Alkhalaf I. Country-Specific Battery Sizing for Intraday Wind and Solar Shifting Across European Power Systems, 2015–2025. Clean Technologies. 2026;8(6):195. doi:10.3390/cleantechnol8060195
BibTeX
@article{Mykhei2026,
author = {Mykhei, Maksym and Taušová, Marcela and Tauš, Peter and Čulková, Katarína and Mudarri, Tawfik and Alkhalaf, Ibrahim},
title = {Country-Specific Battery Sizing for Intraday Wind and Solar Shifting Across European Power Systems, 2015–2025},
journal = {Clean Technologies},
year = {2026},
volume = {8},
number = {6},
pages = {195},
doi = {10.3390/cleantechnol8060195}
}
EUVIMED