EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Photovoltaic Operating-Point Prediction Using Optimised Machine Learning and Polynomial Regression

Retselisitsoe Pebane, Bonginkosi Thango

Clean Technologies · 30.10.2026 · 8 (6) · 177

DOI: 10.3390/cleantechnol8060177 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Clean Technologies, online erschienen am 30.10.2026. Verfasst von Retselisitsoe Pebane und 1 weiteren Autor:innen. Die Arbeit nennt 31 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Accurate photovoltaic (PV) operating-point prediction supports energy-yield assessment, supervisory control, and digital-twin applications, but optimization benefits can be overstated when smooth model-generated data are used. This study benchmarks six standalone metaheuristics and equal-budget random search for tuning support-vector regression (SVR), XGBoost, and multilayer perceptron models that predict maximum power, maximum-power-point voltage and current, open-circuit voltage, and short-circuit current. The public dataset contains 496 model-generated operating records. Model selection used temperature-grouped development validation, while six complete temperature groups were withheld for external-condition evaluation. Each model-search-seed run received 500 candidate evaluations. The selected DE-SVR model achieved an external mean standardized RMSE of 0.0102 and mean R2 of 0.9999. However, degree-two polynomial ridge regression was both simpler and more accurate, with an external mean standardized RMSE of 0.00485. Recomputed run-level Friedman tests found no Holm-significant pairwise optimizer contrasts within any regressor family. The models reproduced the source single-diode temperature response: the maximum-power coefficient was −0.461%/°C in the source records, −0.447%/°C for DE-SVR, and −0.461%/°C for polynomial ridge. Because all partial shading records occur only at 1000 W/m2, these results do not establish performance for partial shading under cloudy or lower-irradiance operating profiles. Generalization was weakest for an entirely unseen 50% shading severity, where current-related R2 values became negative. Population-based metaheuristics therefore offered limited practical value on this smooth response surface. Polynomial regression is the appropriate first-line reference, and measured multi-module field validation remains necessary before deployment.

Zitieren

APA

Pebane, R., & Thango, B. (2026). Photovoltaic Operating-Point Prediction Using Optimised Machine Learning and Polynomial Regression. Clean Technologies, 8(6), 177. https://doi.org/10.3390/cleantechnol8060177

Vancouver

Pebane R, Thango B. Photovoltaic Operating-Point Prediction Using Optimised Machine Learning and Polynomial Regression. Clean Technologies. 2026;8(6):177. doi:10.3390/cleantechnol8060177

BibTeX
@article{Pebane2026,
  author = {Pebane, Retselisitsoe and Thango, Bonginkosi},
  title = {Photovoltaic Operating-Point Prediction Using Optimised Machine Learning and Polynomial Regression},
  journal = {Clean Technologies},
  year = {2026},
  volume = {8},
  number = {6},
  pages = {177},
  doi = {10.3390/cleantechnol8060177}
}