Infrasound and Low-Frequency Noise in Data Center Environments: A Narrative Review Toward Health-Protective Acoustic Design Standards

Megan Rand Wheeler, Brandi Everett, Steven M. Williamson, Victor Prybutok

Clean Technologies · 07.08.2026 · 8 (4) · 126

DOI: 10.3390/cleantechnol8040126 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Clean Technologies, online erschienen am 07.08.2026. Verfasst von Megan Rand Wheeler und 3 weiteren Autor:innen. Die Arbeit wurde bisher 3-mal zitiert (Crossref) und nennt 24 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

The rapid global expansion of data center infrastructure has prompted substantial clean technology research on energy, water, and carbon impacts, while the acoustic health dimension of these facilities remains virtually unstudied. Existing occupational and environmental noise assessments rely on A-weighted (dBA) metrics, which apply more than 26 decibels (dB) of attenuation at 63 hertz (Hz) and exceed 50 dB at infrasound frequencies, sharply discounting their sensitivity to infrasound and low-frequency noise (ILFN) generated by data center cooling fans, heating, ventilation, and air conditioning (HVAC) systems, backup generators, and power transformers. This narrative review synthesizes evidence from established ILFN health research alongside the emerging data center acoustics literature, identifying a consequential gap: no published study has measured the ILFN spectrum of an operational data center, nor examined health outcomes in workers or surrounding communities with respect to sub-audible acoustic exposure. Evidence from wind turbine, industrial, and laboratory contexts documents non-auditory ILFN pathways, including sleep disturbance, cardiovascular stress responses, cognitive impairment, and audiovestibular symptoms—effects that operate below the auditory threshold and are substantially undercounted by standard dBA monitoring. A prioritized research agenda is proposed, beginning with G-weighted and flat-response ILFN characterization of operational data centers across at least 1–200 Hz—a prerequisite for evidence-based acoustic design standards and health-protective infrastructure development consistent with clean technology principles.

Zitieren

APA

Wheeler, M. R., Everett, B., Williamson, S. M., & Prybutok, V. (2026). Infrasound and Low-Frequency Noise in Data Center Environments: A Narrative Review Toward Health-Protective Acoustic Design Standards. Clean Technologies, 8(4), 126. https://doi.org/10.3390/cleantechnol8040126

Vancouver

Wheeler MR, Everett B, Williamson SM, Prybutok V. Infrasound and Low-Frequency Noise in Data Center Environments: A Narrative Review Toward Health-Protective Acoustic Design Standards. Clean Technologies. 2026;8(4):126. doi:10.3390/cleantechnol8040126

BibTeX
@article{Wheeler2026,
  author = {Wheeler, Megan Rand and Everett, Brandi and Williamson, Steven M. and Prybutok, Victor},
  title = {Infrasound and Low-Frequency Noise in Data Center Environments: A Narrative Review Toward Health-Protective Acoustic Design Standards},
  journal = {Clean Technologies},
  year = {2026},
  volume = {8},
  number = {4},
  pages = {126},
  doi = {10.3390/cleantechnol8040126}
}
Kostenlos starten →