Green Hydrogen for Critical-Load Restoration in High-Renewable Power Systems: Energy Not Served Reduction, Economic Value, and Carbon-Resilience Assessment

Nestor F. Guerrero-Rodríguez, Francisco A. Ramírez-Rivera, Rubén D. Ramos Ciprian

Clean Technologies · 08.07.2026 · 8 (4) · 102

DOI: 10.3390/cleantechnol8040102 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Clean Technologies, online erschienen am 08.07.2026. Verfasst von Nestor F. Guerrero-Rodríguez und 2 weiteren Autor:innen. Die Arbeit wurde bisher 2-mal zitiert (Crossref) und nennt 31 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: FONDOCYT.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Green hydrogen is commonly assessed as a renewable fuel or long-duration storage option, but its value as a critical-load restoration resource remains less developed, particularly when produced from curtailed renewable electricity. This study develops a planning-oriented framework to assess green hydrogen for critical-load restoration by linking renewable curtailment, proton-exchange membrane electrolysis, hydrogen storage, fuel-cell reconversion, critical Energy Not Served (ENS) reduction, economic valuation, and carbon-footprint savings. The framework is applied to the Dominican Republic power system as a representative insular case with rapid renewable expansion and limited flexibility. Using monthly preliminary real-operation reports from OC-SENI, the reference case considers 196.46 GWh/year of curtailed non-conventional renewable electricity in 2025, producing 3.78 kt H2/year and 65.5 GWh/year of recoverable electricity. Under the reference screening assumptions, a 25 t H2 storage module would provide 433.29 MWh of usable electricity, fully covering 6 h and 12 h restoration windows for the 30 MW illustrative critical-load case and reducing critical ENS by 60.2% during a 24 h event. The recovered electricity could avoid 43.5 ktCO2/year under the SENI combined-margin grid-displacement case, with higher avoided operational emissions under the diesel-backup displacement sensitivity.

Förderung

  • FONDOCYT

Zitieren

APA

Guerrero-Rodríguez, N. F., Ramírez-Rivera, F. A., & Ciprian, R. D. R. (2026). Green Hydrogen for Critical-Load Restoration in High-Renewable Power Systems: Energy Not Served Reduction, Economic Value, and Carbon-Resilience Assessment. Clean Technologies, 8(4), 102. https://doi.org/10.3390/cleantechnol8040102

Vancouver

Guerrero-Rodríguez NF, Ramírez-Rivera FA, Ciprian RDR. Green Hydrogen for Critical-Load Restoration in High-Renewable Power Systems: Energy Not Served Reduction, Economic Value, and Carbon-Resilience Assessment. Clean Technologies. 2026;8(4):102. doi:10.3390/cleantechnol8040102

BibTeX
@article{GuerreroRodrguez2026,
  author = {Guerrero-Rodríguez, Nestor F. and Ramírez-Rivera, Francisco A. and Ciprian, Rubén D. Ramos},
  title = {Green Hydrogen for Critical-Load Restoration in High-Renewable Power Systems: Energy Not Served Reduction, Economic Value, and Carbon-Resilience Assessment},
  journal = {Clean Technologies},
  year = {2026},
  volume = {8},
  number = {4},
  pages = {102},
  doi = {10.3390/cleantechnol8040102}
}
Kostenlos starten →