Evaluation of the Cooling Effect of an Outdoor Misting Fan for Workers in Hot Environments Wearing Personal Protective Equipment (PPE)
Clean Technologies · 23.01.2025 · 7 (1) · 9
DOI: 10.3390/cleantechnol7010009 ↗Kurz gefasst
Fachartikel in der Zeitschrift Clean Technologies, online erschienen am 23.01.2025. Verfasst von Craig Farnham und 2 weiteren Autor:innen. Die Arbeit wurde bisher 5-mal zitiert (Crossref) und nennt 44 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Japan Society for Promotion of Science “Kakenhi”.
Abstract (Originalsprache)
Heat stress on workers wearing PPE (Personal protective equipment) in hot outdoor environments is of rising concern, especially in cases when rest breaks and clothing changes are impractical. Mist fan evaporative cooling could provide low-energy continuous cooling, even during work activity. The cooling effect of a misting fan was compared to that of a fan alone, as well as natural convection. A thermal mannequin with heat flux sensors at eight body locations was exposed to an outdoor misting fan while being clothed in typical work clothes and PPE. Work clothes were dry or saturated with water to simulate sweat. The distance from the misting fan ranged from 4 m (wetting common) to 7 m (wetting unlikely). On average, the misting fan had a cooling effect of 0.31 met (18.3 W/m2) higher than natural convection when PPE is worn with wet work clothes, and 0.35 met (20.3 W/m2) higher than when PPE is worn with dry work clothes. This equates to reducing the thermal metabolic load from light industrial work to walking about in office work, or from standing to reclining. Under the ISO 7243 international standard for workers in hot environments, this would increase the acceptable WBGT (wet bulb globe temperature) by over 0.6 °C.
Förderung
- Japan Society for Promotion of Science “Kakenhi”
Zitieren
APA
Farnham, C., Yuan, J., & Emura, K. (2025). Evaluation of the Cooling Effect of an Outdoor Misting Fan for Workers in Hot Environments Wearing Personal Protective Equipment (PPE). Clean Technologies, 7(1), 9. https://doi.org/10.3390/cleantechnol7010009
Vancouver
Farnham C, Yuan J, Emura K. Evaluation of the Cooling Effect of an Outdoor Misting Fan for Workers in Hot Environments Wearing Personal Protective Equipment (PPE). Clean Technologies. 2025;7(1):9. doi:10.3390/cleantechnol7010009
BibTeX
@article{Farnham2025,
author = {Farnham, Craig and Yuan, Jihui and Emura, Kazuo},
title = {Evaluation of the Cooling Effect of an Outdoor Misting Fan for Workers in Hot Environments Wearing Personal Protective Equipment (PPE)},
journal = {Clean Technologies},
year = {2025},
volume = {7},
number = {1},
pages = {9},
doi = {10.3390/cleantechnol7010009}
}
EUVIMED