Comparative Assessment of Four Mainstream Wind Load Codes/Standards for Transmission Lines and Their Implications for Tower Responses
CivilEng · 06.11.2026 · 7 (4) · 76
DOI: 10.3390/civileng7040076 ↗Kurz gefasst
Fachartikel in der Zeitschrift CivilEng, online erschienen am 06.11.2026. Verfasst von Ya’nan Tang und 4 weiteren Autor:innen. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: State Grid Zhejiang Electric Power Co., Ltd..
Abstract (Originalsprache)
Differences in reference wind conditions and loading formulations complicate comparisons among transmission-line wind-load standards. This study compares DL/T 5551-2018, ASCE Manual of Practice No. 74 (4th ed., 2020), EN 50341-1:2012, and IEC 60826:2017 for a 220-kV double-circuit suspension tower under a common 50-year, 10-min mean wind reference and approximately comparable open-terrain exposures. The tower, conductor, and ground-wire loading expressions are reorganized into a common algebraic framework, and the resulting equivalent static wind loads are applied to a nonlinear static finite element model. For the upper tower panels, relative EN/IEC differences are larger in effective loading multipliers than in height-variation coefficients. Under transverse wind, IEC produces the largest conductor loads, whereas EN produces the largest ground-wire loads. Before adjustment, base overturning moments obtained using ASCE, EN, and IEC are approximately 15–42% higher than those obtained using DL/T across the investigated wind directions. After applying the adopted adjustment factors, DL/T gives the largest tower-top displacement, while base-shear and overturning-moment rankings vary with wind direction. These case-specific findings demonstrate the importance of considering load distributions and multiple response indicators when interpreting differences among the standards.
Förderung
- State Grid Zhejiang Electric Power Co., Ltd.
Zitieren
APA
Tang, Y., Yang, J., Zheng, W., Feng, J., & Wang, Z. (2026). Comparative Assessment of Four Mainstream Wind Load Codes/Standards for Transmission Lines and Their Implications for Tower Responses. CivilEng, 7(4), 76. https://doi.org/10.3390/civileng7040076
Vancouver
Tang Y, Yang J, Zheng W, Feng J, Wang Z. Comparative Assessment of Four Mainstream Wind Load Codes/Standards for Transmission Lines and Their Implications for Tower Responses. CivilEng. 2026;7(4):76. doi:10.3390/civileng7040076
BibTeX
@article{Tang2026,
author = {Tang, Ya’nan and Yang, Jian and Zheng, Wenzhe and Feng, Jie and Wang, Zhenguo},
title = {Comparative Assessment of Four Mainstream Wind Load Codes/Standards for Transmission Lines and Their Implications for Tower Responses},
journal = {CivilEng},
year = {2026},
volume = {7},
number = {4},
pages = {76},
doi = {10.3390/civileng7040076}
}