Fachartikel in der Zeitschrift CivilEng, online erschienen am 06.11.2026. Verfasst von Ya’nan Tang und 4 weiteren Autor:innen. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: State Grid Zhejiang Electric Power Co., Ltd..

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Differences in reference wind conditions and loading formulations complicate comparisons among transmission-line wind-load standards. This study compares DL/T 5551-2018, ASCE Manual of Practice No. 74 (4th ed., 2020), EN 50341-1:2012, and IEC 60826:2017 for a 220-kV double-circuit suspension tower under a common 50-year, 10-min mean wind reference and approximately comparable open-terrain exposures. The tower, conductor, and ground-wire loading expressions are reorganized into a common algebraic framework, and the resulting equivalent static wind loads are applied to a nonlinear static finite element model. For the upper tower panels, relative EN/IEC differences are larger in effective loading multipliers than in height-variation coefficients. Under transverse wind, IEC produces the largest conductor loads, whereas EN produces the largest ground-wire loads. Before adjustment, base overturning moments obtained using ASCE, EN, and IEC are approximately 15–42% higher than those obtained using DL/T across the investigated wind directions. After applying the adopted adjustment factors, DL/T gives the largest tower-top displacement, while base-shear and overturning-moment rankings vary with wind direction. These case-specific findings demonstrate the importance of considering load distributions and multiple response indicators when interpreting differences among the standards.

Förderung

  • State Grid Zhejiang Electric Power Co., Ltd.

Zitieren

APA

Tang, Y., Yang, J., Zheng, W., Feng, J., & Wang, Z. (2026). Comparative Assessment of Four Mainstream Wind Load Codes/Standards for Transmission Lines and Their Implications for Tower Responses. CivilEng, 7(4), 76. https://doi.org/10.3390/civileng7040076

Vancouver

Tang Y, Yang J, Zheng W, Feng J, Wang Z. Comparative Assessment of Four Mainstream Wind Load Codes/Standards for Transmission Lines and Their Implications for Tower Responses. CivilEng. 2026;7(4):76. doi:10.3390/civileng7040076

BibTeX
@article{Tang2026,
  author = {Tang, Ya’nan and Yang, Jian and Zheng, Wenzhe and Feng, Jie and Wang, Zhenguo},
  title = {Comparative Assessment of Four Mainstream Wind Load Codes/Standards for Transmission Lines and Their Implications for Tower Responses},