Parametric Study of the Physical Responses of NSM CFRP-Strengthened RC T-Beams in the Negative Moment Region
CivilEng · 20.10.2025 · 6 (4) · 56
DOI: 10.3390/civileng6040056 ↗Kurz gefasst
Fachartikel in der Zeitschrift CivilEng, online erschienen am 20.10.2025. Verfasst von Yanuar Haryanto und 7 weiteren Autor:innen. Die Arbeit wurde bisher 4-mal zitiert (Crossref) und nennt 75 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: National Science and Technology Council, Institute for Research and Community Service.
Abstract (Originalsprache)
This study presented a comprehensive finite element (FE) investigation into the flexural behavior of RC T-beams strengthened in the negative moment region using near-surface mounted (NSM) carbon-fiber-reinforced polymers (CFRP) rods. A three-dimensional nonlinear FE model was developed and validated against experimental data, achieving close agreement with normalized mean square error values as low as 0.006 and experimental-to-numerical ratios ranging from 0.95 to 1.04. The validated model was then employed to conduct a systematic parametric analysis considering CFRP rod diameter, concrete compressive strength, longitudinal reinforcement ratio, and FRP material type. The results showed that increasing CFRP diameter from 6 to 10 mm enhanced ultimate load by up to 47.51% and improved stiffness by 1.48 times. Higher concrete compressive strength contributed to stiffness gains exceeding 50.00%, although this improvement was accompanied by reductions in ductility. Beams with reinforcement ratios up to 2.90% achieved peak loads of 309.61 kN, but ductility declined. Comparison among FRP materials indicated that CFRP and AFRP offered superior strength and stiffness, whereas BFRP provided a more balanced combination of strength and deformation capacity.
Förderung
- National Science and Technology Council
- Institute for Research and Community Service
Zitieren
APA
Haryanto, Y., Sudibyo, G. H., Hu, H., Hsiao, F., Nugroho, L., Saputro, D. N., Suryanto, H. R., & Haryanto, A. E. C. (2025). Parametric Study of the Physical Responses of NSM CFRP-Strengthened RC T-Beams in the Negative Moment Region. CivilEng, 6(4), 56. https://doi.org/10.3390/civileng6040056
Vancouver
Haryanto Y, Sudibyo GH, Hu H, Hsiao F, Nugroho L, Saputro DN, et al. Parametric Study of the Physical Responses of NSM CFRP-Strengthened RC T-Beams in the Negative Moment Region. CivilEng. 2025;6(4):56. doi:10.3390/civileng6040056
BibTeX
@article{Haryanto2025,
author = {Haryanto, Yanuar and Sudibyo, Gathot Heri and Hu, Hsuan-Teh and Hsiao, Fu-Pei and Nugroho, Laurencius and Saputro, Dani Nugroho and Suryanto, Habib Raihan and Haryanto, Abel Earnesta Christopher},
title = {Parametric Study of the Physical Responses of NSM CFRP-Strengthened RC T-Beams in the Negative Moment Region},
journal = {CivilEng},
year = {2025},
volume = {6},
number = {4},
pages = {56},
doi = {10.3390/civileng6040056}
}