EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Development of Pyramidal Microwells for Enhanced Cell Spheroid Formation in a Cell-on-Chip Microfluidic System for Cardiac Differentiation of Mouse Embryonic Stem Cells

Tepparit Wongpakham, Thanapat Chunfong, Wutthinan Jeamsaksiri iD, Kriengkai Chessadangkul, Sudchaya Bhanpattanakul, Wirakan Kallayanathum iD, Theerawat Tharasanit iD, Alongkorn Pimpin iD

Cells · 2024

DOI: 10.3390/cells13242132 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Cells, 2024. Verfasst von Tepparit Wongpakham und 7 weiteren Autor:innen. Beteiligte Einrichtung: Department of Mechanical Engineering, Faculty of Engineering, Chulalongkorn University, Bangkok 10330, Thailand. Hauptthemen laut MEDLINE: Mouse Embryonic Stem Cells, Cell Differentiation, Spheroids, Cellular, Lab-On-A-Chip Devices. Die Arbeit wurde bisher 7-mal zitiert (Crossref) und nennt 52 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Chulalongkorn University, Thailand Science Research and Innovation Fund, Chulalongkorn University.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Three-dimensional (3D) tissue culture models provide in vivo-like conditions for studying cell physiology. This study aimed to examine the efficiency of pyramidal microwell geometries in microfluidic devices on spheroid formation, cell growth, viability, and differentiation in mouse embryonic stem cells (mESCs). The static culture using the hanging drop (HD) method served as a control. The microfluidic chips were fabricated to have varying pyramidal tip angles, including 66°, 90°, and 106°. From flow simulations, when the tip angle increased, streamline distortion decreased, resulting in more uniform flow and a lower velocity gradient near the spheroids. These findings demonstrate the significant influence of microwell geometry on fluid dynamics. The 90° microwells provide optimal conditions, including uniform flow and reduced shear stress, while maintaining the ability for waste removal, resulting in superior spheroid growth compared to the HD method and other microwell designs. From the experiments, by Day 3, spheroids in the 90° microwells reached approximately 400 µm in diameter which was significantly larger than those in the 66° microwells, 106° microwells, and HD cultures. Brachyury gene expression in the 90° microwells was four times higher than the HD method, indicating enhanced mesodermal differentiation essential for cardiac differentiation. Immunofluorescence staining confirmed cardiomyocyte differentiation. In conclusion, microwell geometry significantly influences 3D cell culture outcomes. The pyramidal microwells with a 90° tip angle proved most effective in promoting spheroid growth and cardiac differentiation of mESC differentiation, providing insights for optimizing microfluidic systems in tissue engineering and regenerative medicine.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Mouse Embryonic Stem CellsCell DifferentiationSpheroids, CellularLab-On-A-Chip DevicesMyocytes, CardiacAnimalsMiceCell Culture TechniquesCell ProliferationCell SurvivalMicrofluidics

Stichwörter der Autor:innen

cell spheroidembryoid bodymicrofluidicsmicrowellsperfusionpyramidal tip angles

Autor:innen und Institutionen

  • Department of Mechanical Engineering, Faculty of Engineering, Chulalongkorn University, Bangkok 10330, Thailand.
  • Thai Microelectronics Center, National Electronics and Computer Technology Center, Chachoengsao 24000, Thailand.
  • Department of Pathology, Faculty of Veterinary Science, Chulalongkorn University, Bangkok 10330, Thailand.
  • Center of Excellence for Veterinary Clinical Stem Cells and Bioengineering, Chulalongkorn University, Bangkok 10330, Thailand.
  • Department of Obstetrics, Gynaecology and Reproduction, Faculty of Veterinary Science, Chulalongkorn University, Bangkok 10330, Thailand.
  • Micro/Nano Electromechanical Integrated Device Research Unit, Faculty of Engineering, Chulalongkorn University, Bangkok 10330, Thailand.

ORCID-Profile: Wutthinan Jeamsaksiri, Wirakan Kallayanathum, Theerawat Tharasanit, Alongkorn Pimpin

Förderung

  • Chulalongkorn University
  • Thailand Science Research and Innovation Fund, Chulalongkorn University

Zitieren

APA

Wongpakham, T., Chunfong, T., Jeamsaksiri, W., Chessadangkul, K., Bhanpattanakul, S., Kallayanathum, W., Tharasanit, T., & Pimpin, A. (2024). Development of Pyramidal Microwells for Enhanced Cell Spheroid Formation in a Cell-on-Chip Microfluidic System for Cardiac Differentiation of Mouse Embryonic Stem Cells. Cells. https://doi.org/10.3390/cells13242132

Vancouver

Wongpakham T, Chunfong T, Jeamsaksiri W, Chessadangkul K, Bhanpattanakul S, Kallayanathum W, et al. Development of Pyramidal Microwells for Enhanced Cell Spheroid Formation in a Cell-on-Chip Microfluidic System for Cardiac Differentiation of Mouse Embryonic Stem Cells. Cells. 2024. doi:10.3390/cells13242132

BibTeX
@article{Wongpakham2024,
  author = {Wongpakham, Tepparit and Chunfong, Thanapat and Jeamsaksiri, Wutthinan and Chessadangkul, Kriengkai and Bhanpattanakul, Sudchaya and Kallayanathum, Wirakan and Tharasanit, Theerawat and Pimpin, Alongkorn},
  title = {Development of Pyramidal Microwells for Enhanced Cell Spheroid Formation in a Cell-on-Chip Microfluidic System for Cardiac Differentiation of Mouse Embryonic Stem Cells},
  journal = {Cells},
  year = {2024},
  doi = {10.3390/cells13242132}
}
Kostenlos starten →