EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Enhancing H2O2 Generation Using Activated Carbon Electrocatalyst Cathode: Experimental and Computational Insights on Current, Cathode Design, and Reactor Configuration

Maria Del Mar Cerrillo-Gonzalez iD, Amir Taqieddin iD, Stephanie Sarrouf, Nima Sakhaee, Juan Manuel Paz-García iD, Akram N Alshawabkeh, Muhammad Fahad Ehsan iD

Catalysts · 18.02.2025 · 15 (2) · 189

DOI: 10.3390/catal15020189 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Catalysts, online erschienen am 18.02.2025. Verfasst von Maria Del Mar Cerrillo-Gonzalez und 6 weiteren Autor:innen. Beteiligte Einrichtung: Department of Chemical Engineering, Faculty of Sciences, University of Malaga, 29010 Malaga, Spain. Die Arbeit wurde bisher 6-mal zitiert (Crossref) und nennt 37 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: NIEHS NIH HHS, European Union’s Horizon 2020 research and innovation program, Superfund Research Program of the National Institute of Environmental Health Sciences (NIEHS).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Granular activated carbon (GAC) serves as a cost-efficient electrocatalyst cathode in electrochemical water treatment. This study investigates the impact of current intensity and cathode mesh size on the electrocatalytic generation of reactive oxygen species (ROS), i.e., hydrogen peroxide (H2O2) and hydroxyl radicals (•OH), for removing p-nitrophenol (PNP) as a representative contaminant. The findings suggest that these parameters exert a factorial effect on PNP removal, which is statistically endorsed via the analysis of variance. The −20 + 40 mesh GAC exhibited superior electrocatalytic performance due to its optimal balance of porosity and active surface area. Additionally, the reactor configuration was also studied. Employing two reactors in series configuration resulted in a 23% increase in H2O2 generation and a 32% enhancement in overall PNP removal compared with the single reactor configuration. This enhancement is attributed to (i) the enhanced electroactive area, (ii) the greater retention time of PNP over the electrocatalyst surface, and (iii) the increased dissolved oxygen and H2O2 content in the second reactor, promoting the overall H2O2 generation. Numerical simulations were conducted to compute H2O2 concentration profiles, providing a detailed representation of the physical, chemical, and electrochemical processes. The model exhibited a high degree of accuracy compared with the experimental measurements, with R2 values ranging from ~0.76 to 0.99 and MAE values between ~0.04 and 0.23 mg/L. The simulation results highlight a strong interplay between H2O2 generation, its reaction kinetics during PNP removal, and electrode utilization efficiency. These findings emphasize the importance of optimizing the applied current magnitude and reactor operation duration to maximize electrode efficiency and H2O2 generation and utilization, while minimizing electrochemical bubble blockage. Overall, this study provides fundamental insights to optimize the electroactive area for enhanced ROS generation toward efficient contaminant removal, supporting sustainable groundwater remediation technologies in the face of emerging pollutants.

Schlagwörter

Stichwörter der Autor:innen

Bayesian optimizationGACH2O2 generationelectrocatalysisnumerical simulationsreactor configurationwater treatment

Autor:innen und Institutionen

  • Department of Chemical Engineering, Faculty of Sciences, University of Malaga, 29010 Malaga, Spain.
  • Department of Mechanical and Industrial Engineering, Northeastern University, Boston, MA 02115, USA.
  • Department of Civil and Environmental Engineering, Northeastern University, Boston, MA 02115, USA.

ORCID-Profile: Maria Del Mar Cerrillo-Gonzalez, Amir Taqieddin, Juan Manuel Paz-García, Muhammad Fahad Ehsan

Förderung

  • NIEHS NIH HHS
  • European Union’s Horizon 2020 research and innovation program
  • Superfund Research Program of the National Institute of Environmental Health Sciences (NIEHS)
  • National Institutes of Health (NIH)

Zitieren

APA

Cerrillo-Gonzalez, M. D. M., Taqieddin, A., Sarrouf, S., Sakhaee, N., Paz-García, J. M., Alshawabkeh, A. N., & Ehsan, M. F. (2025). Enhancing H2O2 Generation Using Activated Carbon Electrocatalyst Cathode: Experimental and Computational Insights on Current, Cathode Design, and Reactor Configuration. Catalysts, 15(2), 189. https://doi.org/10.3390/catal15020189

Vancouver

Cerrillo-Gonzalez MDM, Taqieddin A, Sarrouf S, Sakhaee N, Paz-García JM, Alshawabkeh AN, et al. Enhancing H2O2 Generation Using Activated Carbon Electrocatalyst Cathode: Experimental and Computational Insights on Current, Cathode Design, and Reactor Configuration. Catalysts. 2025;15(2):189. doi:10.3390/catal15020189

BibTeX
@article{CerrilloGonzalez2025,
  author = {Cerrillo-Gonzalez, Maria Del Mar and Taqieddin, Amir and Sarrouf, Stephanie and Sakhaee, Nima and Paz-García, Juan Manuel and Alshawabkeh, Akram N and Ehsan, Muhammad Fahad},
  title = {Enhancing H2O2 Generation Using Activated Carbon Electrocatalyst Cathode: Experimental and Computational Insights on Current, Cathode Design, and Reactor Configuration},
  journal = {Catalysts},
  year = {2025},
  volume = {15},
  number = {2},
  pages = {189},
  doi = {10.3390/catal15020189}
}
Kostenlos starten →