EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Diagnostic Accuracy of Ex Vivo Confocal Microscopy for Surgical Margin Assessment of High-Risk Nodular Basal Cell Carcinoma

William Stramke, Luca Tonellotto, Emmanuella Guenova iD, François Kuonen iD

Cancers · 16.09.2025 · 17 (18) · 3019

DOI: 10.3390/cancers17183019 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Cancers, online erschienen am 16.09.2025. Verfasst von William Stramke und 3 weiteren Autor:innen. Beteiligte Einrichtung: Department of Dermatology and Venereology, Lausanne University Hospital, University of Lausanne, 1011 Lausanne, Switzerland. Die Arbeit wurde bisher 5-mal zitiert (Crossref) und nennt 32 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Background

Accurate margin assessment during surgical treatment is essential to prevent recurrences of BCC. Mohs surgery or alternative peripheral and deep en-face margin assessment (PDEMA) based on conventional histopathology are considered the gold standard for excising high-risk BCC, as it allows stepwise and complete examination of peripheral and deep margins. However, it is labor-intensive and time-consuming. EVCM has emerged as a promising alternative, allowing rapid intraoperative evaluation of fresh excised tissue.

Objective

To assess the diagnostic accuracy of EVCM in a PDEMA workflow of high-risk nodular BCCs.

Methods

A retrospective monocentric study was conducted at the Lausanne University Hospital (CHUV) between March 2024 and May 2025. A total of 51 patients with histologically confirmed nodular BCCs considered as high-risk and thus addressed for EVCM-assisted excision were included, yielding 171 surgical margin samples. EVCM and conventional histology-based PDEMA analyses were compared.

Results

EVCM achieved an overall sensitivity of 93.8% (95% CI: 71.7–98.9%) and specificity of 98.7% (95% CI: 95.2–99.7%) compared to conventional histology. The positive and negative predictive values were 88.2% (95% CI: 63.6–97.4%) and 99.4% (95% CI: 96.4–99.9%), respectively.

Conclusion

EVCM demonstrates high diagnostic accuracy for the intraoperative PDEMA of high-risk, nodular BCC. Its integration in PDEMA surgical workflows may improve efficiency, although confirmatory studies are needed in broader clinical settings.

Schlagwörter

Stichwörter der Autor:innen

Mohs surgerybasal cell carcinomaconfocal laser scanning microscopyhistologyintraoperative imagingnodularperipheral and deep en-face margin assessmentskin cancersurgical margins

Autor:innen und Institutionen

  • Department of Dermatology and Venereology, Lausanne University Hospital, University of Lausanne, 1011 Lausanne, Switzerland.

ORCID-Profile: Emmanuella Guenova, François Kuonen

Zitieren

APA

Stramke, W., Tonellotto, L., Guenova, E., & Kuonen, F. (2025). Diagnostic Accuracy of Ex Vivo Confocal Microscopy for Surgical Margin Assessment of High-Risk Nodular Basal Cell Carcinoma. Cancers, 17(18), 3019. https://doi.org/10.3390/cancers17183019

Vancouver

Stramke W, Tonellotto L, Guenova E, Kuonen F. Diagnostic Accuracy of Ex Vivo Confocal Microscopy for Surgical Margin Assessment of High-Risk Nodular Basal Cell Carcinoma. Cancers. 2025;17(18):3019. doi:10.3390/cancers17183019

BibTeX
@article{Stramke2025,
  author = {Stramke, William and Tonellotto, Luca and Guenova, Emmanuella and Kuonen, François},
  title = {Diagnostic Accuracy of Ex Vivo Confocal Microscopy for Surgical Margin Assessment of High-Risk Nodular Basal Cell Carcinoma},
  journal = {Cancers},
  year = {2025},
  volume = {17},
  number = {18},
  pages = {3019},
  doi = {10.3390/cancers17183019}
}
Kostenlos starten →