Advanced External Beam Stereotactic Radiotherapy for Skull Base Reirradiation

He Wang iD, Fahed M Alsanea, Dong Joo Rhee, Xiaodong Zhang, Wei Liu iD, Jinzhong Yang iD, Zhifei Wen, Yao Zhao, Tyler D Williamson iD, Rachel A Hunter iD, Peter A Balter, Tina M Briere iD und 8 weitere

Cancers · 05.02.2025 · 17 (3) · 540

DOI: 10.3390/cancers17030540 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Cancers, online erschienen am 05.02.2025. Verfasst von He Wang und 19 weiteren Autor:innen. Beteiligte Einrichtung: Radiation Physics, University of Texas M.D. Anderson Cancer Center, Houston, TX 77030, USA. Die Arbeit wurde bisher 2-mal zitiert (Crossref) und nennt 81 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Background/Objectives: Stereotactic body radiation therapy (SBRT) for skull base reirradiation is particularly challenging, as patients have already received substantial radiation doses to the region, and nearby normal organs may have approached their tolerance limit from prior treatments. In this study, we reviewed the characteristics and capabilities of four advanced external beam radiation delivery systems and four modern treatment planning systems and evaluated the treatment plan quality of each technique using skull base reirradiation patient cases.

Methods

SBRT plans were generated for sixteen skull base reirradiation patients using four modalities: the GK plan for the Elekta Leksell Gamma Knife Perfexion/ICON, the CyberKnife (CK) plan for the Accuray CyberKnife, the intensity-modulated proton therapy (IMPT) plan for the Hitachi ProBeat-FR proton therapy machine, and the volumetric-modulated arc therapy (VMAT) plan for the Varian TrueBeam STx. These plans were evaluated and compared using two novel gradient indices in addition to traditional dosimetry metrics for targets and organs at risk (OARs). The steepest border gradient quantified the percent prescription dose fall-off per millimeter at the boundary between the target and adjacent critical structures. This gradient index highlighted the system’s ability to spare nearby critical OARs. The volume gradient assessed the extent of dose spread outside the target toward the patient’s body.

Results

All plans achieved comparable target coverage and conformity, while IMPT and VMAT demonstrated significantly better uniformity. The GK plans exhibited the highest border gradient, up to 20.9%/mm, followed by small-spot-size IMPT plans and CK plans. Additionally, IMPT plans showed the benefit of reduced dose spread in low-dose regions and the lowest maximum and mean doses to the brainstem and carotid artery.

Conclusions

The advanced external beam radiotherapy modalities evaluated in this study are well-suited for SBRT in skull base reirradiation, which demands precise targeting of tumors with highly conformal doses and steep dose gradients to protect nearby normal structures.

Schlagwörter

Stichwörter der Autor:innen

CyberKnifeGamma Knifedose gradientexternal beam radiation therapyintensity-modulated proton therapyproton therapyreirradiationskull base cancerstereotactic body radiation therapyvolumetric modulated radiation therapy

Autor:innen und Institutionen

  • Radiation Physics, University of Texas M.D. Anderson Cancer Center, Houston, TX 77030, USA.
  • Medical Physics, Mayo Clinic College of Medicine and Science, Phoenix, AZ 85054, USA.
  • Radiation Oncology, Hoag Memorial Hospital, Hoag Cancer Center, Newport Beach, CA 92663, USA.
  • Radiation Therapeutic Physics, University of Texas M.D. Anderson Cancer Center, Houston, TX 77030, USA.
  • Radiation Oncology, University of Texas M.D. Anderson Cancer Center, Houston, TX 77030, USA.

ORCID-Profile: He Wang, Wei Liu, Jinzhong Yang, Tyler D Williamson, Rachel A Hunter, Tina M Briere, Amy C Moreno, Jay P Reddy, Jack Phan

Zitieren

APA

Wang, H., Alsanea, F. M., Rhee, D. J., Zhang, X., Liu, W., Yang, J., Wen, Z., Zhao, Y., Williamson, T. D., Hunter, R. A., Balter, P. A., Briere, T. M., Zhu, R. X., Lee, A., Moreno, A. C., Reddy, J. P., Garden, A. S., Rosenthal, D. I., Gunn, G. B., & Phan, J. (2025). Advanced External Beam Stereotactic Radiotherapy for Skull Base Reirradiation. Cancers, 17(3), 540. https://doi.org/10.3390/cancers17030540

Vancouver

Wang H, Alsanea FM, Rhee DJ, Zhang X, Liu W, Yang J, et al. Advanced External Beam Stereotactic Radiotherapy for Skull Base Reirradiation. Cancers. 2025;17(3):540. doi:10.3390/cancers17030540

BibTeX
@article{Wang2025,
  author = {Wang, He and Alsanea, Fahed M and Rhee, Dong Joo and Zhang, Xiaodong and Liu, Wei and Yang, Jinzhong and Wen, Zhifei and Zhao, Yao and Williamson, Tyler D and Hunter, Rachel A and Balter, Peter A and Briere, Tina M and Zhu, Ronald X and Lee, Anna and Moreno, Amy C and Reddy, Jay P and Garden, Adam S and Rosenthal, David I and Gunn, Gary B and Phan, Jack},
  title = {Advanced External Beam Stereotactic Radiotherapy for Skull Base Reirradiation},
  journal = {Cancers},
  year = {2025},
  volume = {17},
  number = {3},
  pages = {540},
  doi = {10.3390/cancers17030540}
}
Kostenlos starten →