The Applications and Pitfalls of Cone-Beam Computed Tomography-Based Synthetic Computed Tomography for Adaptive Evaluation in Pencil-Beam Scanning Proton Therapy
Cancers · 22.10.2023 · 15 (20) · 5101
DOI: 10.3390/cancers15205101 ↗Kurz gefasst
Fachartikel in der Zeitschrift Cancers, online erschienen am 22.10.2023. Verfasst von Pingfang Tsai und 14 weiteren Autor:innen. Beteiligte Einrichtung: New York Proton Center, New York, NY 10035, USA. Die Arbeit wurde bisher 8-mal zitiert (Crossref) und nennt 32 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: NCI NIH HHS.
Abstract (Originalsprache)
Purpose
The study evaluates the efficacy of cone-beam computed tomography (CBCT)-based synthetic CTs (sCT) as a potential alternative to verification CT (vCT) for enhanced treatment monitoring and early adaptation in proton therapy.
Methods
Seven common treatment sites were studied. Two sets of sCT per case were generated: direct-deformed (DD) sCT and image-correction (IC) sCT. The image qualities and dosimetric impact of the sCT were compared to the same-day vCT.
Results
The sCT agreed with vCT in regions of homogeneous tissues such as the brain and breast; however, notable discrepancies were observed in the thorax and abdomen. The sCT outliers existed for DD sCT when there was an anatomy change and for IC sCT in low-density regions. The target coverage exhibited less than a 5% variance in most DD and IC sCT cases when compared to vCT. The Dmax of serial organ-at-risk (OAR) in sCT plans shows greater deviation from vCT than small-volume dose metrics (D0.1cc). The parallel OAR volumetric and mean doses remained consistent, with average deviations below 1.5%.
Conclusion
The use of sCT enables precise treatment and prompt early adaptation for proton therapy. The quality assurance of sCT is mandatory in the early stage of clinical implementation.
Schlagwörter
Stichwörter der Autor:innen
Autor:innen und Institutionen
- New York Proton Center, New York, NY 10035, USA.
- Proton Center, Taipei Medical University, Taipei 11031, Taiwan.
- Department of Radiation Oncology, Taipei Medical University, Taipei 11031, Taiwan.
- California Protons Center Therapy Center, San Diego, CA 92121, USA.
- Department of Radiation Oncology, Memorial Sloan Kettering Cancer Center, New York, NY 10065, USA.
- Department of Radiation Oncology, Montefiore Medical Center, Bronx, NY 10467, USA.
ORCID-Profile: Charles B Simone, Casey L Johnson, Chin-Cheng Chen
Förderung
- NCI NIH HHS
Zitieren
APA
Tsai, P., Tseng, Y. L., Shen, B., Ackerman, C., Zhai, H. A., Yu, F., Simone, C. B., Choi, J. I., Lee, N. Y., Kabarriti, R., Lazarev, S., Johnson, C. L., Liu, J., Chen, C. C., & Lin, H. (2023). The Applications and Pitfalls of Cone-Beam Computed Tomography-Based Synthetic Computed Tomography for Adaptive Evaluation in Pencil-Beam Scanning Proton Therapy. Cancers, 15(20), 5101. https://doi.org/10.3390/cancers15205101
Vancouver
Tsai P, Tseng YL, Shen B, Ackerman C, Zhai HA, Yu F, et al. The Applications and Pitfalls of Cone-Beam Computed Tomography-Based Synthetic Computed Tomography for Adaptive Evaluation in Pencil-Beam Scanning Proton Therapy. Cancers. 2023;15(20):5101. doi:10.3390/cancers15205101
BibTeX
@article{Tsai2023,
author = {Tsai, Pingfang and Tseng, Yu-Lun and Shen, Brian and Ackerman, Christopher and Zhai, Huifang A and Yu, Francis and Simone, Charles B and Choi, J Isabelle and Lee, Nancy Y and Kabarriti, Rafi and Lazarev, Stanislav and Johnson, Casey L and Liu, Jiayi and Chen, Chin-Cheng and Lin, Haibo},
title = {The Applications and Pitfalls of Cone-Beam Computed Tomography-Based Synthetic Computed Tomography for Adaptive Evaluation in Pencil-Beam Scanning Proton Therapy},
journal = {Cancers},
year = {2023},
volume = {15},
number = {20},
pages = {5101},
doi = {10.3390/cancers15205101}
}
EUVIMED