Acoustic Radiation Force Impulse (ARFI) Elastography of Focal Splenic Lesions: Feasibility and Diagnostic Potential
Cancers · 12.10.2023 · 15 (20) · 4964
DOI: 10.3390/cancers15204964 ↗Kurz gefasst
Fachartikel in der Zeitschrift Cancers, online erschienen am 12.10.2023. Verfasst von Amjad Alhyari und 7 weiteren Autor:innen. Beteiligte Einrichtung: Department of Gastroenterology, Endocrinology, Metabolism and Infectious Diseases, University Hospital Giessen and Marburg, Philipp University of Mar…. Die Arbeit wurde bisher 2-mal zitiert (Crossref) und nennt 39 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).
Abstract (Originalsprache)
Purpose
Nontraumatic focal splenic lesions (FSL) are rare, and the need for tissue diagnosis must be weighed against the very high risk of bleeding after a splenic biopsy. The aim of this study was to explore the feasibility and diagnostic potential of acoustic radiation force impulse (ARFI) elastography as a noninvasive method for different benign and malignant FSLs. No human studies on the elastographic characteristics of FSL exist.
Methods
This was a retrospective analysis of 34 patients with FSLs, who underwent abdominal B-mode ultrasound (B-US), contrast-enhanced ultrasound (CEUS), and standardized ARFI examinations between October 2021 and December 2022 at our university hospital. The inclusion criteria were: (i) FSL size ≥ 1 cm; (ii) 10 valid ARFI measurements of the FSL, as well as of the normal splenic parenchyma (NSP) as an in vivo reference; and (iii) diagnostic confirmation of FSL etiology based on histological examination (8/34; 23.5%) or clinical evaluation, which included a clinical and sonographic follow-up (FU), CEUS morphology, and/or morphology on cross-sectional imaging (26/34; 76.5%). CEUS was performed on all patients and the FSLs were classified according to the current guidelines; cross-sectional imaging was available for 29/34 (85.3%). The mean FU duration was 25.8 ± 30.5 months. The mean ARFI velocity (MAV) of the FSL (MAVL), the NSP (MAVP), and the ratio of the MAVL to the MAVP (MAVL/P) were calculated and compared.
Results
Of the 34 FSLs, 13 (38.2%) were malignant (mFSL) and 21 (61.8%) were benign (bFSL). The MAVL of all 34 FSLs (2.74 ± 0.71 m/s) was lower than the MAVP (3.20 ± 0.59 m/s), p = 0.009, with a mean MAVL/P ratio of 0.90 ± 0.34. No significant differences in the MAVL were observed between the mFSL (2.66 ± 0.67 m/s) and bFSL (2.79 ± 0.75 m/s). There were also no significant differences between the MAVP in patients with mFSL (3.24 ± 0.68 m/s) as compared to that in the patients with bFSL (3.18 ± 0.55 m/s). Likewise, the MAV L/P ratio did not differ between the mFSL (0.90 ± 0.41 m/s) and bFSL (0.90 ± 0.30 m/s) groups.
Conclusion
ARFI elastography is feasible in evaluating the stiffness of FSLs. The lesions’ stiffness was lower than that of the NSP, regardless of the FSL etiology. However, differentiation between benign and malignant FSL with the help of this elastographic method does not appear possible. Larger prospective studies are needed to validate these findings.
Schlagwörter
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Gastroenterology, Endocrinology, Metabolism and Infectious Diseases, University Hospital Giessen and Marburg, Philipp University of Marburg, 35033 Marburg, Germany.
- Interdisciplinary Centre of Ultrasound Diagnostics, University Hospital Giessen and Marburg, Philipp University of Marburg, 35033 Marburg, Germany.
- Department of Haematology, Oncology and Immunology, University Hospital Giessen and Marburg, Philipps University of Marburg, 35033 Marburg, Germany.
- Department Allgemeine Innere Medizin (DAIM), Kliniken Hirslanden Bern, Beau Site, Salem und Permanence, 3013 Bern, Switzerland.
- Institute of Pathology, University Hospital Giessen and Marburg, Philipps University of Marburg, 35033 Marburg, Germany.
- Department of Biomedical Imaging and Imaging-Guided Therapy, Medical University of Vienna, 1090 Vienna, Austria.
ORCID-Profile: Amjad Alhyari, Christian Görg, Corinna Trenker, Christoph Frank Dietrich, Christina C Westhoff, Ehsan Safai Zadeh, Hajo Findeisen
Zitieren
APA
Alhyari, A., Görg, C., Tahat, S., Trenker, C., Dietrich, C. F., Westhoff, C. C., Safai Zadeh, E., & Findeisen, H. (2023). Acoustic Radiation Force Impulse (ARFI) Elastography of Focal Splenic Lesions: Feasibility and Diagnostic Potential. Cancers, 15(20), 4964. https://doi.org/10.3390/cancers15204964
Vancouver
Alhyari A, Görg C, Tahat S, Trenker C, Dietrich CF, Westhoff CC, et al. Acoustic Radiation Force Impulse (ARFI) Elastography of Focal Splenic Lesions: Feasibility and Diagnostic Potential. Cancers. 2023;15(20):4964. doi:10.3390/cancers15204964
BibTeX
@article{Alhyari2023,
author = {Alhyari, Amjad and Görg, Christian and Tahat, Suhaib and Trenker, Corinna and Dietrich, Christoph Frank and Westhoff, Christina C and Safai Zadeh, Ehsan and Findeisen, Hajo},
title = {Acoustic Radiation Force Impulse (ARFI) Elastography of Focal Splenic Lesions: Feasibility and Diagnostic Potential},
journal = {Cancers},
year = {2023},
volume = {15},
number = {20},
pages = {4964},
doi = {10.3390/cancers15204964}
}
EUVIMED