Fachartikel in der Zeitschrift Cancers, online erschienen am 17.07.2023. Verfasst von Janna Morawitz und 17 weiteren Autor:innen. Beteiligte Einrichtung: Department of Diagnostic and Interventional Radiology, Medical Faculty, University Dusseldorf, D-40225 Dusseldorf, Germany. Die Arbeit wurde bisher 11-mal zitiert (Crossref) und nennt 33 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Deutsche Forschungsgemeinschaft.
Abstract (Originalsprache)
Background
This study compares the diagnostic potential of conventional staging (computed tomography (CT), axillary sonography and bone scintigraphy), whole-body magnetic resonance imaging (MRI) and whole-body 18F-fluorodeoxyglucose positron emission tomography (18F-FDG PET/)MRI for N and M staging in newly diagnosed breast cancer.
Methods
A total of 208 patients with newly diagnosed breast cancer were prospectively included in this study and underwent contrast-enhanced thoracoabdominal CT, bone scintigraphy and axillary sonography as well as contrast-enhanced whole-body 18F-FDG PET/MRI. The datasets were analyzed with respect to lesion localization and characterization. Histopathology and follow-up imaging served as the reference standard. A McNemar test was used to compare the diagnostic performance of conventional staging, MRI and 18F-FDG PET/MRI and a Wilcoxon test was used to compare differences in true positive findings for nodal staging.
Results
Conventional staging determined the N stage with a sensitivity of 80.9%, a specificity of 99.2%, a PPV (positive predictive value) of 98.6% and a NPV (negative predictive value) of 87.4%. The corresponding results for MRI were 79.6%, 100%, 100% and 87.0%, and were 86.5%, 94.1%, 91.7% and 90.3% for 18F-FDG PET/MRI. 18F-FDG PET/MRI was significantly more sensitive in determining malignant lymph nodes than conventional imaging and MRI (p < 0.0001 and p = 0.0005). Furthermore, 18F-FDG PET/MRI accurately estimated the clinical lymph node stage in significantly more cases than conventional imaging and MRI (each p < 0.05). Sensitivity, specificity, PPV and NPV for the M stage in conventional staging were 83.3%, 98.5%, 76.9% and 98.9%, respectively. The corresponding results for both MRI and 18F-FDG PET/MRI were 100.0%, 98.5%, 80.0% and 100.0%. No significant differences between the imaging modalities were seen for the staging of distant metastases. Conclusions:18F-FDG PET/MRI detects lymph node metastases in significantly more patients and estimates clinical lymph node stage more accurately than conventional imaging and MRI. No significant differences were found between imaging modalities with respect to the detection of distant metastases.
Schlagwörter
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Diagnostic and Interventional Radiology, Medical Faculty, University Dusseldorf, D-40225 Dusseldorf, Germany.
- Department of Diagnostic and Interventional Radiology and Neuroradiology, University Hospital Essen, University of Duisburg-Essen, D-45147 Essen, Germany.
- Department Gynecology and Obstetrics, University Hospital Essen, University of Duisburg-Essen, D-45147 Essen, Germany.
- Department of Gynecology, Medical Faculty, University Dusseldorf, D-40225 Dusseldorf, Germany.
- Institute of Pathology, Medical Faculty, University Hospital Duesseldorf, Heinrich-Heine-University, D-40204 Duesseldorf, Germany.
- Department of Nuclear Medicine, German Cancer Consortium (DKTK)-University Hospital Essen, University of Duisburg-Essen, D-45147 Essen, Germany.
ORCID-Profile: Frederic Dietzel, Lena Häberle, Andreas Stang
Förderung
- Deutsche Forschungsgemeinschaft
Zitieren
APA
Morawitz, J., Bruckmann, N. M., Jannusch, K., Dietzel, F., Milosevic, A., Bittner, A. K., Hoffmann, O., Mohrmann, S., Ruckhäberle, E., Häberle, L., Fendler, W. P., Herrmann, K., Giesel, F. L., Antoch, G., Umutlu, L., Kowall, B., Stang, A., & Kirchner, J. (2023). Conventional Imaging, MRI and 18F-FDG PET/MRI for N and M Staging in Patients with Newly Diagnosed Breast Cancer. Cancers, 15(14), 3646. https://doi.org/10.3390/cancers15143646
Vancouver
Morawitz J, Bruckmann NM, Jannusch K, Dietzel F, Milosevic A, Bittner AK, et al. Conventional Imaging, MRI and 18F-FDG PET/MRI for N and M Staging in Patients with Newly Diagnosed Breast Cancer. Cancers. 2023;15(14):3646. doi:10.3390/cancers15143646
BibTeX
@article{Morawitz2023,
author = {Morawitz, Janna and Bruckmann, Nils-Martin and Jannusch, Kai and Dietzel, Frederic and Milosevic, Aleksandar and Bittner, Ann-Kathrin and Hoffmann, Oliver and Mohrmann, Svjetlana and Ruckhäberle, Eugen and Häberle, Lena and Fendler, Wolfgang Peter and Herrmann, Ken and Giesel, Frederik Lars and Antoch, Gerald and Umutlu, Lale and Kowall, Bernd and Stang, Andreas and Kirchner, Julian},
title = {Conventional Imaging, MRI and 18F-FDG PET/MRI for N and M Staging in Patients with Newly Diagnosed Breast Cancer},
journal = {Cancers},
year = {2023},
volume = {15},
number = {14},
pages = {3646},
doi = {10.3390/cancers15143646}
}
EUVIMED