EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Comparative Seismic Performance of Hybrid Reinforced Concrete–Masonry Buildings Retrofitted with Different Strengthening Systems: A Nonlinear Finite Element Study

Mehdi Öztürk, Muhammet Daştan

Buildings · 23.11.2026 · 16 (23) · 4681

DOI: 10.3390/buildings16234681 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Buildings, online erschienen am 23.11.2026. Verfasst von Mehdi Öztürk und 1 weiteren Autor:innen. Die Arbeit nennt 62 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

This study investigates the nonlinear seismic behavior of hybrid reinforced concrete (RC)–masonry buildings and comparatively evaluates the effectiveness of different retrofitting strategies. An existing rural school building consisting of a RC basement and two unreinforced masonry stories was selected as a case study. A detailed three-dimensional finite element model was developed in ABAQUS (Dassault Systèmes SIMULIA Corp., Johnston, RI, USA) using the structural geometry and experimentally determined material properties. Nonlinear static pushover analyses were performed in both principal directions to evaluate seismic capacity, displacement demands, plastic strain distributions, and damage mechanisms. Five strengthening strategies were investigated: carbon fiber-reinforced polymer wrapping (CFRP), reinforced concrete jacketing (RC-Jacketing), steel-braced frames, combined steel bracing and CFRP wrapping, and RC shear walls. The results revealed significant differences in structural stiffness, displacement response, and damage development among the retrofitting configurations. Among the investigated strengthening strategies, CFRP wrapping provided the smallest improvement in global stiffness, reducing the fundamental vibration periods by only 1.25% and 7.32% in the X and Y directions, respectively, with corresponding displacement demands of 13.34 and 5.23 mm. Although CFRP wrapping, RC-Jacketing, and steel-based interventions reduced lateral displacement demands, they could not adequately prevent brittle damage mechanisms in the existing masonry walls. RC shear wall retrofitting provided the most favorable overall seismic performance, reducing the fundamental vibration periods to 0.046 and 0.040 s and limiting the spectral displacement demands (Sd) to 1.84 and 1.83 mm in the X and Y directions, respectively. The R5 model satisfied the masonry wall strength criterion associated with the Controlled Damage (CD) level under TBEC-2018, with the contribution of shear-deficient masonry walls remaining below the 40% threshold. However, this finding does not represent a comprehensive performance verification of the entire strengthened structural system. The findings demonstrate that effective seismic retrofitting of hybrid structures depends not only on increasing material strength but also on improving global lateral stiffness, load-transfer mechanisms, and damage control.

Zitieren

APA

Öztürk, M., & Daştan, M. (2026). Comparative Seismic Performance of Hybrid Reinforced Concrete–Masonry Buildings Retrofitted with Different Strengthening Systems: A Nonlinear Finite Element Study. Buildings, 16(23), 4681. https://doi.org/10.3390/buildings16234681

Vancouver

Öztürk M, Daştan M. Comparative Seismic Performance of Hybrid Reinforced Concrete–Masonry Buildings Retrofitted with Different Strengthening Systems: A Nonlinear Finite Element Study. Buildings. 2026;16(23):4681. doi:10.3390/buildings16234681

BibTeX
@article{ztrk2026,
  author = {Öztürk, Mehdi and Daştan, Muhammet},
  title = {Comparative Seismic Performance of Hybrid Reinforced Concrete–Masonry Buildings Retrofitted with Different Strengthening Systems: A Nonlinear Finite Element Study},
  journal = {Buildings},
  year = {2026},
  volume = {16},
  number = {23},
  pages = {4681},
  doi = {10.3390/buildings16234681}
}
Kostenlos starten →