EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

A Physics and Vision Framework for Rapid Post-Earthquake Assessment of RC Double-Column Piers

Hairong Deng, Honghong Song, Yu Gao, Sivakumar Kulasegaram, Abdullah Alshahrani

Buildings · 20.11.2026 · 16 (22) · 4631

DOI: 10.3390/buildings16224631 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Buildings, online erschienen am 20.11.2026. Verfasst von Hairong Deng und 4 weiteren Autor:innen. Die Arbeit nennt 34 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Najran University.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Rapid post-earthquake assessment of reinforced concrete (RC) double-column piers is hindered by incomplete response records and the uncertain relationship between visible damage and global mechanical performance. Using quasi-static tests of two specimens with different transverse reinforcement configurations, hysteretic responses, mechanical degradation, and visible damage were examined. A Physics–Vision Response-Driven Assessment (PV-RDA) framework was proposed to determine performance levels from mechanical responses, constrain plausible performance states using concrete spalling and exposed reinforcement area ratios, and assess cross-evidence compatibility through the minimum performance-level difference. Mechanical degradation and visible damage evolved asynchronously. In specimen P2, which was detailed with spiral reinforcement, normalized secant stiffness decreased to 0.40 before quantifiable spalling or reinforcement exposure was observed. At the final reference points, normalized secant stiffness values were 0.06 and 0.07 for P1 and P2, respectively, despite markedly different spalling area ratios of 37.13% and 12.61%. Across eight representative loading points, all mechanically determined levels fell within the visually supported state sets, yielding zero minimum performance-level differences. However, visual evidence could not uniquely distinguish performance levels. PV-RDA preserves source-specific assessments under incomplete information and enables compatibility checks when both evidence sources are available.

Förderung

  • Najran University

Zitieren

APA

Deng, H., Song, H., Gao, Y., Kulasegaram, S., & Alshahrani, A. (2026). A Physics and Vision Framework for Rapid Post-Earthquake Assessment of RC Double-Column Piers. Buildings, 16(22), 4631. https://doi.org/10.3390/buildings16224631

Vancouver

Deng H, Song H, Gao Y, Kulasegaram S, Alshahrani A. A Physics and Vision Framework for Rapid Post-Earthquake Assessment of RC Double-Column Piers. Buildings. 2026;16(22):4631. doi:10.3390/buildings16224631

BibTeX
@article{Deng2026,
  author = {Deng, Hairong and Song, Honghong and Gao, Yu and Kulasegaram, Sivakumar and Alshahrani, Abdullah},
  title = {A Physics and Vision Framework for Rapid Post-Earthquake Assessment of RC Double-Column Piers},
  journal = {Buildings},
  year = {2026},
  volume = {16},
  number = {22},
  pages = {4631},
  doi = {10.3390/buildings16224631}
}
Kostenlos starten →