EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Spatial Performance of Wide-Span Public Buildings for Temporary Collective Shelter: Building Performance Evaluation After the 2023 Kahramanmaraş Earthquakes

Tülay Canbolat, Makbule Berfin Büker, Yağmur Turğut

Buildings · 18.11.2026 · 16 (22) · 4596

DOI: 10.3390/buildings16224596 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Buildings, online erschienen am 18.11.2026. Verfasst von Tülay Canbolat und 2 weiteren Autor:innen. Die Arbeit nennt 61 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Türkiye Disaster Response Plan.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Following the 6 February 2023 Kahramanmaraş earthquakes, wide-span public buildings were used for temporary collective shelter despite limited evidence concerning their spatial suitability and supporting infrastructure. This study evaluates the plan-based spatial performance of 39 public buildings across three provinces, including 33 used for collective shelter, through a criterion-based Building Performance Evaluation approach. Architectural plans, field data, and retrospectively reported peak user loads were used to assess functional spatial composition, existing and convertible shelter area, sanitation provision, and quantitative accessibility. Descriptive analyses, humanitarian reference comparisons, hierarchical clustering, and sensitivity and robustness assessments were conducted. Among buildings with reported user-load data, 30.3% met the 3.5 m2/person reference based on Net Shelter Area, increasing to 48.5% when convertible areas were included. However, sanitation provision was the governing capacity constraint, individually or jointly, in 22 of the 39 buildings under existing spatial capacity and 35 when convertible areas were considered. Three exploratory spatial profiles were identified, although area-to-user ratios did not differ significantly among clusters and cluster stability was limited. Because user loads were retrospectively estimated, demand-based indicators represent screening measures rather than verified overnight occupancy conditions. The findings suggest that pre-disaster shelter planning should distinguish existing shelter area, convertible spatial reserves, and infrastructure-supported capacity rather than relying on total floor area or a single theoretical capacity estimate.

Förderung

  • Türkiye Disaster Response Plan

Zitieren

APA

Canbolat, T., Büker, M. B., & Turğut, Y. (2026). Spatial Performance of Wide-Span Public Buildings for Temporary Collective Shelter: Building Performance Evaluation After the 2023 Kahramanmaraş Earthquakes. Buildings, 16(22), 4596. https://doi.org/10.3390/buildings16224596

Vancouver

Canbolat T, Büker MB, Turğut Y. Spatial Performance of Wide-Span Public Buildings for Temporary Collective Shelter: Building Performance Evaluation After the 2023 Kahramanmaraş Earthquakes. Buildings. 2026;16(22):4596. doi:10.3390/buildings16224596

BibTeX
@article{Canbolat2026,
  author = {Canbolat, Tülay and Büker, Makbule Berfin and Turğut, Yağmur},
  title = {Spatial Performance of Wide-Span Public Buildings for Temporary Collective Shelter: Building Performance Evaluation After the 2023 Kahramanmaraş Earthquakes},
  journal = {Buildings},
  year = {2026},
  volume = {16},
  number = {22},
  pages = {4596},
  doi = {10.3390/buildings16224596}
}
Kostenlos starten →