Experimental Analysis of Tuned Liquid Dampers with Various Damping Screen Geometries and Porosity Ratios Under Dynamic Excitations
Buildings · 18.11.2026 · 16 (22) · 4590
DOI: 10.3390/buildings16224590 ↗Kurz gefasst
Fachartikel in der Zeitschrift Buildings, online erschienen am 18.11.2026. Verfasst von Ali Bozer und 1 weiteren Autor:innen. Die Arbeit nennt 32 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Scientific and Technological Research Council of Türkiye.
Abstract (Originalsprache)
The purpose of this study is to evaluate the vibration control performance of tuned liquid dampers (TLDs) equipped with internal perforated and slat screens. The effect of screen geometry and porosity on nonlinear sloshing and structural response reduction was investigated through a series of shake table tests. Harmonic tests at fixed frequencies and seismic excitations using four scaled earthquake records (El Centro, Kobe, Loma Prieta, and Sakarya) were applied to the test frame. A parametric analysis was performed by varying the water depth (4.5 cm to 6.5 cm) and screen porosity (40%, 50%, 60%). The results indicate that a 40% porosity gave the lowest added damping ratio and response reduction, consistent with overdamping of the sloshing mode, whereas a 60% porosity gave the largest added damping ratio among the screens. At the best tested depth (5.0 cm), screens reduced the peak roof acceleration by up to 27% under the Kobe record, against 17.5% for the plain TLD, but gave no consistent improvement under the other records. The root-mean-square (RMS) roof accelerations, an average measure of the response level over the record, were reduced by up to 49%. The benefit of the screens and the best water depth depend on the input.
Förderung
- Scientific and Technological Research Council of Türkiye
Zitieren
APA
Bozer, A., & Atar, Ö. (2026). Experimental Analysis of Tuned Liquid Dampers with Various Damping Screen Geometries and Porosity Ratios Under Dynamic Excitations. Buildings, 16(22), 4590. https://doi.org/10.3390/buildings16224590
Vancouver
Bozer A, Atar Ö. Experimental Analysis of Tuned Liquid Dampers with Various Damping Screen Geometries and Porosity Ratios Under Dynamic Excitations. Buildings. 2026;16(22):4590. doi:10.3390/buildings16224590
BibTeX
@article{Bozer2026,
author = {Bozer, Ali and Atar, Özer},
title = {Experimental Analysis of Tuned Liquid Dampers with Various Damping Screen Geometries and Porosity Ratios Under Dynamic Excitations},
journal = {Buildings},
year = {2026},
volume = {16},
number = {22},
pages = {4590},
doi = {10.3390/buildings16224590}
}
EUVIMED