Bayesian Filtering for Temperature-Compensated Damage Detection in Hysteretic Structures: A Monte Carlo Comparison of Particle and Kalman-Type Filters
Buildings · 17.11.2026 · 16 (22) · 4589
DOI: 10.3390/buildings16224589 ↗Kurz gefasst
Fachartikel in der Zeitschrift Buildings, online erschienen am 17.11.2026. Verfasst von Lucio Pinello und 1 weiteren Autor:innen. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).
Abstract (Originalsprache)
Online estimation of stiffness parameters from vibration data is a common building block of temperature-compensated damage detection. This study compares Bayesian filters for this task on a three-degree-of-freedom structure with a Bouc–Wen hysteretic element under varying temperatures: sequential importance resampling particle filters (SIR PFs), an action-aided particle filter (A-SIR PF) and its reformulations, a damage-factor PF, and extended, unscented and ensemble Kalman filters. Tracking, detection and localisation are assessed over paired Monte Carlo simulations of step and progressive degradation, at equal false-alarm rates. With the same model, the Kalman-type filters give the lowest errors, and adaptive systematic resampling brings the PFs to within 2–6% of them. Prior knowledge helps when it enters the transition model: a damage-factor PF, which includes a temperature–stiffness law learned from healthy data and the constraint that damage cannot increase the stiffness, is the most accurate filter, with errors on the healthy springs about 20% lower than those of the Kalman-type filters. The least-action principle, used as the objective of trajectory estimation, leads to a fixed-lag smoother that reduces the errors of the best filter by 25–62%, with a 1 s delay. At large thermal excursions, the environmental normalisation is necessary, and an autoencoder with standardised inputs and a conditional regression of the stiffness on the temperature are equally effective.
Zitieren
APA
Pinello, L., & Lomazzi, L. (2026). Bayesian Filtering for Temperature-Compensated Damage Detection in Hysteretic Structures: A Monte Carlo Comparison of Particle and Kalman-Type Filters. Buildings, 16(22), 4589. https://doi.org/10.3390/buildings16224589
Vancouver
Pinello L, Lomazzi L. Bayesian Filtering for Temperature-Compensated Damage Detection in Hysteretic Structures: A Monte Carlo Comparison of Particle and Kalman-Type Filters. Buildings. 2026;16(22):4589. doi:10.3390/buildings16224589
BibTeX
@article{Pinello2026,
author = {Pinello, Lucio and Lomazzi, Luca},
title = {Bayesian Filtering for Temperature-Compensated Damage Detection in Hysteretic Structures: A Monte Carlo Comparison of Particle and Kalman-Type Filters},
journal = {Buildings},
year = {2026},
volume = {16},
number = {22},
pages = {4589},
doi = {10.3390/buildings16224589}
}