Buckling and Mechanical Behavior of Single Through-Type and Plate-Reinforced X-Shaped Concrete-Filled Steel Tubular Columns
Buildings · 17.11.2026 · 16 (22) · 4586
DOI: 10.3390/buildings16224586 ↗Kurz gefasst
Fachartikel in der Zeitschrift Buildings, online erschienen am 17.11.2026. Verfasst von Xufeng Wang und 6 weiteren Autor:innen. Die Arbeit nennt 46 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).
Abstract (Originalsprache)
The axial resistance and out-of-plane buckling of concrete-filled steel tubular (CFST) X-columns depend in part on the configuration of their crossing. This study compared two CFST X-column specimens, one single through-type (ST) and one plate-reinforced (PR), to assess how crossing detail relates to axial response and bending distribution. The PR configuration incorporated an intermediate plate at the crossing, while nominal tube dimensions, member lengths, branch angle, and infill were matched between configurations. Axial compression tests provided load–actuator-travel histories, while three-point post-test lateral measurements characterized residual bending around the crossing. Finite element models compared the first out-of-plane modes and stress distributions around the crossing. The PR specimen reached a 34.9% higher peak load and carried more load across the shared pre-peak displacement range. Both specimens developed overall out-of-plane buckling, while the PR specimen showed a steeper peak-normalized post-peak load decline. Post-test bending was most prominent near the ST crossing but in the adjacent lower tube for PR; joint-center chord deviations were 24.5 and 16.5 mm, respectively. Numerical modes and stress contours showed a corresponding redistribution of deformation and stress around the reinforced crossing. These findings link X-joint detailing to axial resistance and the location of out-of-plane bending, providing evidence for assessing CFST X-column configurations.
Zitieren
APA
Wang, X., Zhang, Y., Wu, J., Ge, Z., Chen, X., Yuan, Y., & Zhang, D. (2026). Buckling and Mechanical Behavior of Single Through-Type and Plate-Reinforced X-Shaped Concrete-Filled Steel Tubular Columns. Buildings, 16(22), 4586. https://doi.org/10.3390/buildings16224586
Vancouver
Wang X, Zhang Y, Wu J, Ge Z, Chen X, Yuan Y, et al. Buckling and Mechanical Behavior of Single Through-Type and Plate-Reinforced X-Shaped Concrete-Filled Steel Tubular Columns. Buildings. 2026;16(22):4586. doi:10.3390/buildings16224586
BibTeX
@article{Wang2026,
author = {Wang, Xufeng and Zhang, Yongfei and Wu, Jiangwen and Ge, Zhengchen and Chen, Xiuyuan and Yuan, Yongkai and Zhang, Dunfu},
title = {Buckling and Mechanical Behavior of Single Through-Type and Plate-Reinforced X-Shaped Concrete-Filled Steel Tubular Columns},
journal = {Buildings},
year = {2026},
volume = {16},
number = {22},
pages = {4586},
doi = {10.3390/buildings16224586}
}
EUVIMED