Seismic Drift Mitigation and Base Shear Attenuation in Multi-Story Steel Moment Frames Equipped with Fluid Viscous Dampers Across Contrasting Soil Amplification Regimes
Buildings · 17.11.2026 · 16 (22) · 4580
DOI: 10.3390/buildings16224580 ↗Kurz gefasst
Fachartikel in der Zeitschrift Buildings, online erschienen am 17.11.2026. Verfasst von Ertuğrul Çambay und 1 weiteren Autor:innen. Die Arbeit nennt 31 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).
Abstract (Originalsprache)
This study investigates the dynamic efficacy of Fluid Viscous Dampers (FVDs) in mitigating lateral story drift and attenuating seismic base shear forces in multi-story steel moment-resisting frames (MRFs) subjected to contrasting geotechnical site conditions. Archetype steel structures with 5, 10, and 15 stories were designed in full compliance with the Turkish Building Earthquake Code (TBDY-2018) and AISC 360-16 specifications, considering hard rock (ZA) and soft, deep sedimentary soil deposits (ZE) for high-seismicity coordinates along the East Anatolian Fault zone (Pazarcık, Kahramanmaraş). A suite of 11 real earthquake acceleration pairs (22 horizontal components) compiled from the AFAD TADAS database was spectrally matched to code-compliant target elastic response spectra using continuous wavelet transforms. Direct integration nonlinear time-history analyses (NL-THA) were executed using the Newmark average acceleration method. Modal eigenvalue analyses confirm that supplemental diagonal FVDs preserve the fundamental natural vibration periods of the frames (T1 = 0.70 s, 1.53 s, and 1.53 s for the 5-, 10-, and 15-story archetypes, respectively) without imposing secondary elastic stiffness penalties. The nonlinear dynamic findings demonstrate that FVD integration reduces peak lateral floor displacements by 54.59% to 88.05% and suppresses maximum base shear demands by 69.10% to 85.29% across all heights and shaking directions. Notably, under soft soil (ZE) excitations where unprotected bare frames develop severe interstory drift concentrations (up to 3.18%), the FVD systems consistently restrict maximum interstory drift ratios (IDRs) below the 0.80% damage-control limit, keeping peak drift demands within the threshold conventionally associated with elastic or near-elastic frame response, thereby indicating a low likelihood of plastic hinge formation and precluding second-order P − Δ collapse mechanisms.
Zitieren
APA
Çambay, E., & Çontay, C. (2026). Seismic Drift Mitigation and Base Shear Attenuation in Multi-Story Steel Moment Frames Equipped with Fluid Viscous Dampers Across Contrasting Soil Amplification Regimes. Buildings, 16(22), 4580. https://doi.org/10.3390/buildings16224580
Vancouver
Çambay E, Çontay C. Seismic Drift Mitigation and Base Shear Attenuation in Multi-Story Steel Moment Frames Equipped with Fluid Viscous Dampers Across Contrasting Soil Amplification Regimes. Buildings. 2026;16(22):4580. doi:10.3390/buildings16224580
BibTeX
@article{ambay2026,
author = {Çambay, Ertuğrul and Çontay, Cenk},
title = {Seismic Drift Mitigation and Base Shear Attenuation in Multi-Story Steel Moment Frames Equipped with Fluid Viscous Dampers Across Contrasting Soil Amplification Regimes},
journal = {Buildings},
year = {2026},
volume = {16},
number = {22},
pages = {4580},
doi = {10.3390/buildings16224580}
}