Economic Assessment of Pipe-Network Thermal Storage in Fifth-Generation District Heating and Cooling Systems
Buildings · 16.11.2026 · 16 (22) · 4569
DOI: 10.3390/buildings16224569 ↗Kurz gefasst
Fachartikel in der Zeitschrift Buildings, online erschienen am 16.11.2026. Verfasst von Lingqi Su und 2 weiteren Autor:innen. Die Arbeit nennt 29 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Shanghai Pujiang Program, Anhui Province Key Laboratory of Intelligent Building and Building Energy Saving.
Abstract (Originalsprache)
Fifth-generation district heating and cooling (5GDHC) systems have attracted increasing attention because they can supply heating and cooling simultaneously, enable buildings to act as thermal prosumers, and facilitate the recovery of low-grade waste heat. Because these networks operate near ambient temperature, their temperature can be modulated over a relatively wide range in both winter and summer, creating the potential to use the pipe network for both heat and cold storage. However, the economic value of using this inherent thermal capacity and the benefit of increasing it through pipe enlargement remain unclear. This study develops a dynamic thermo-hydraulic optimization framework that represents bidirectional flow, water and ground thermal states, temperature-dependent heat-pump and chiller performance, pumping electricity, and annualized system costs. A genetic algorithm is used offline to compare daily-constant and predictive network-temperature control at three pipe-capacity levels in a synthetic 5GDHC system developed using Beijing weather and tariff data. Predictive control reduced the annualized cost at all three pipe-capacity levels, with savings ranging from 0.17% to 0.52%. Reductions in monthly demand charges and active-equipment capacity costs provided most of the economic benefit, whereas the energy charge changed only slightly or increased. Increasing every pipe by one or two catalog sizes raised the network water volume by 32.1% and 69.5% and reduced pumping electricity by 51.8% and 74.0%, but increased the annualized cost by 0.14% and 0.44%, respectively. The results show that the thermal capacity already available in a 5GDHC network can provide modest operational flexibility, but enlarging pipes solely to obtain additional thermal storage did not show a substantial economic advantage in the investigated case.
Förderung
- Shanghai Pujiang Program
- Anhui Province Key Laboratory of Intelligent Building and Building Energy Saving
Zitieren
APA
Su, L., Zhang, Y., & Li, S. (2026). Economic Assessment of Pipe-Network Thermal Storage in Fifth-Generation District Heating and Cooling Systems. Buildings, 16(22), 4569. https://doi.org/10.3390/buildings16224569
Vancouver
Su L, Zhang Y, Li S. Economic Assessment of Pipe-Network Thermal Storage in Fifth-Generation District Heating and Cooling Systems. Buildings. 2026;16(22):4569. doi:10.3390/buildings16224569
BibTeX
@article{Su2026,
author = {Su, Lingqi and Zhang, Yongming and Li, Shanshou},
title = {Economic Assessment of Pipe-Network Thermal Storage in Fifth-Generation District Heating and Cooling Systems},
journal = {Buildings},
year = {2026},
volume = {16},
number = {22},
pages = {4569},
doi = {10.3390/buildings16224569}
}
EUVIMED