EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Investigating the Behavior of Ductile Steel Links Used for Improving the Behavior of Hybrid Reinforced Concrete Frame

Israa Hasan Nayel, Waleed Khaleel Nayel, Ali Ghamari, Mehmet Palanci

Buildings · 16.11.2026 · 16 (22) · 4567

DOI: 10.3390/buildings16224567 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Buildings, online erschienen am 16.11.2026. Verfasst von Israa Hasan Nayel und 3 weiteren Autor:innen. Die Arbeit nennt 19 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Previous earthquakes and experience from damage to reinforced concrete (RC) frames have confirmed the susceptibility of structural systems to damage. Also, due to the main feature of the RC system, the formation of plastic hinges at the two ends of the beams, its repair is complicated. In line with this, the growth of precast concrete frames has been highly susceptible to damage. Accordingly, in this paper, the behavior of a precast concrete frame equipped with an innovative steel link, focusing on the performance of the ductile steel link, is carried out parametrically and numerically. Results indicate that the stiffeners on the ductile steel link affect the behavior of the steel link. The ratio of the stiffeners’ thickness to the beam flange thickness does not impact the response. For a given length-to-height ratio of the link, the stiffeners-to-link-length ratio significantly influences the response, with the normalized moment showing greater sensitivity than the normalized shear force. The response remains approximately linear at small rotations, but nonlinear behavior begins at about 0.002 rad, after which differences between the geometric and thickness ratios become increasingly pronounced, particularly in the normalized moment response. The nonlinear behavior of the systems starts at around shear plastic capacity, Vp, corresponding to a rotation of 0.002 rad. Accordingly, it can be concluded that the shear capacity of the models is between Vp ≤ V ≤ 1.5Vp.

Zitieren

APA

Nayel, I. H., Nayel, W. K., Ghamari, A., & Palanci, M. (2026). Investigating the Behavior of Ductile Steel Links Used for Improving the Behavior of Hybrid Reinforced Concrete Frame. Buildings, 16(22), 4567. https://doi.org/10.3390/buildings16224567

Vancouver

Nayel IH, Nayel WK, Ghamari A, Palanci M. Investigating the Behavior of Ductile Steel Links Used for Improving the Behavior of Hybrid Reinforced Concrete Frame. Buildings. 2026;16(22):4567. doi:10.3390/buildings16224567

BibTeX
@article{Nayel2026,
  author = {Nayel, Israa Hasan and Nayel, Waleed Khaleel and Ghamari, Ali and Palanci, Mehmet},
  title = {Investigating the Behavior of Ductile Steel Links Used for Improving the Behavior of Hybrid Reinforced Concrete Frame},
  journal = {Buildings},
  year = {2026},
  volume = {16},
  number = {22},
  pages = {4567},
  doi = {10.3390/buildings16224567}
}
Kostenlos starten →