A Numerical Investigation of Prestress-Induced Tensile-Damage Control in GFRP-Reinforced Concrete Beams Using an Equivalent Cooling Method
Buildings · 13.11.2026 · 16 (22) · 4527
DOI: 10.3390/buildings16224527 ↗Kurz gefasst
Fachartikel in der Zeitschrift Buildings, online erschienen am 13.11.2026. Verfasst von Shijun Huang und 5 weiteren Autor:innen. Die Arbeit nennt 52 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Key Technologies for Foundation Design and Construction of Flexible Anti-Eddy-Current Fiber-Reinforced Composite Bars for Reactors.
Abstract (Originalsprache)
Prestressing may delay tensile-damage initiation in glass-fibre reinforced polymer (GFRP)-reinforced concrete beams, but the relationship between transferred reinforcement stress and the subsequent tensile-damage development requires consistent numerical evaluation. This study develops and calibrates a three-dimensional finite-element model based on the concrete damaged plasticity (CDP) framework against published four-point bending experimental data. For the Goldston benchmark beam, the FE-predicted first-cracking load, peak load and deflection at peak load differ from the corresponding experimental values by 4.3%, 10.2% and 6.5%, respectively. Five parametric beam configurations are investigated: non-prestressed steel-reinforced B40, non-prestressed GFRP-reinforced C40, and prestressed GFRP-reinforced beams P4, P8 and P12. An equivalent cooling method is employed to introduce prestress, and the mean post-transfer GFRP axial stress is extracted from the numerical results. Using a consistent numerical damage-onset criterion of DAMAGET ≥ 0.001 within a predefined bottom midspan region, the numerical tensile-damage onset loads are 20.54, 16.39, 26.51, 35.70 and 45.51 kN for B40, C40, P4, P8 and P12, respectively. The mean post-transfer GFRP axial stresses in P4, P8 and P12 are 57.27, 114.54 and 171.79 MPa, respectively. Compared with the non-prestressed GFRP reference C40, the corresponding numerical tensile-damage onset loads increase by 61.7%, 117.8% and 177.7%, respectively. At a common loading-point displacement of 5 mm, the element-volume fraction of the predefined midspan region with DAMAGET > 0.05 decreases from 28.39% for C40 to 16.54% for P12, although the local maximum damage does not decrease monotonically. The results demonstrate that prestress can delay numerical tensile-damage initiation and reduce the spatial extent of appreciable midspan tensile damage under the adopted embedded-reinforcement model, without directly predicting physical crack width.
Förderung
- Key Technologies for Foundation Design and Construction of Flexible Anti-Eddy-Current Fiber-Reinforced Composite Bars for Reactors
Zitieren
APA
Huang, S., Jia, Y., Peng, S., Song, Z., Zhou, D., & Feng, R. (2026). A Numerical Investigation of Prestress-Induced Tensile-Damage Control in GFRP-Reinforced Concrete Beams Using an Equivalent Cooling Method. Buildings, 16(22), 4527. https://doi.org/10.3390/buildings16224527
Vancouver
Huang S, Jia Y, Peng S, Song Z, Zhou D, Feng R. A Numerical Investigation of Prestress-Induced Tensile-Damage Control in GFRP-Reinforced Concrete Beams Using an Equivalent Cooling Method. Buildings. 2026;16(22):4527. doi:10.3390/buildings16224527
BibTeX
@article{Huang2026,
author = {Huang, Shijun and Jia, Yihang and Peng, Saiqing and Song, Zijian and Zhou, Dengfeng and Feng, Ruoqiang},
title = {A Numerical Investigation of Prestress-Induced Tensile-Damage Control in GFRP-Reinforced Concrete Beams Using an Equivalent Cooling Method},
journal = {Buildings},
year = {2026},
volume = {16},
number = {22},
pages = {4527},
doi = {10.3390/buildings16224527}
}