EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Research on Energy-Saving Retrofit Optimization of Existing Multi-Story Residential Buildings in Suzhou, Anhui Province, China, Based on ANN Surrogate Models and Multi-Objective Optimization

Zhongcheng Duan, Shibo He, Zhou Hao, Leilei Wang

Buildings · 06.11.2026 · 16 (21) · 4448

DOI: 10.3390/buildings16214448 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Buildings, online erschienen am 06.11.2026. Verfasst von Zhongcheng Duan und 3 weiteren Autor:innen. Die Arbeit nennt 30 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: China University of Mining and Technology.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

To address the trade-offs among energy savings, thermal comfort, and retrofit cost in existing multi-story residential buildings in cold climate regions, this study developed a retrofit optimization framework integrating building performance simulation, artificial neural network (ANN) surrogate models, and multi-objective optimization. A typical six-story residential building in Suzhou, Anhui Province, was selected as the case building. The DesignBuilder model was calibrated against one month of measured summer data, and the design variables were screened using Morris sensitivity analysis. Latin hypercube sampling was then employed to generate 5000 samples for training separate surrogate models of annual net electricity-use intensity (ANEUI), annual discomfort hours (DH), and initial retrofit cost per unit floor area (IRC). The optimization performance of NSGA-III, MOPSO, and NSGA-III-PSO was compared, and a compromise solution was identified using a combined subjective-objective weighting TOPSIS method. NSGA-III-PSO showed a better balance between convergence and objective-space coverage. EnergyPlus re-simulation indicated that the compromise solution reduced ANEUI from 60.29 to 35.98 kWh/(m2·a) and DH from 5413.2 to 4012.5 h, corresponding to reductions of 40.3% and 25.8%, respectively, while the IRC was 398.9 CNY/m2. The proposed framework provides quantitative decision support for integrated residential retrofits under comparable climatic conditions.

Förderung

  • China University of Mining and Technology

Zitieren

APA

Duan, Z., He, S., Hao, Z., & Wang, L. (2026). Research on Energy-Saving Retrofit Optimization of Existing Multi-Story Residential Buildings in Suzhou, Anhui Province, China, Based on ANN Surrogate Models and Multi-Objective Optimization. Buildings, 16(21), 4448. https://doi.org/10.3390/buildings16214448

Vancouver

Duan Z, He S, Hao Z, Wang L. Research on Energy-Saving Retrofit Optimization of Existing Multi-Story Residential Buildings in Suzhou, Anhui Province, China, Based on ANN Surrogate Models and Multi-Objective Optimization. Buildings. 2026;16(21):4448. doi:10.3390/buildings16214448

BibTeX
@article{Duan2026,
  author = {Duan, Zhongcheng and He, Shibo and Hao, Zhou and Wang, Leilei},
  title = {Research on Energy-Saving Retrofit Optimization of Existing Multi-Story Residential Buildings in Suzhou, Anhui Province, China, Based on ANN Surrogate Models and Multi-Objective Optimization},
  journal = {Buildings},
  year = {2026},
  volume = {16},
  number = {21},
  pages = {4448},
  doi = {10.3390/buildings16214448}
}