Response-Specific Applicability of Equivalent Thermal Models for 3D-Printed Ribbed Wall Envelopes
Buildings · 23.10.2026 · 16 (21) · 4213
DOI: 10.3390/buildings16214213 ↗Kurz gefasst
Fachartikel in der Zeitschrift Buildings, online erschienen am 23.10.2026. Verfasst von Xiaoyi Hu und 2 weiteren Autor:innen. Die Arbeit nennt 64 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Applied Technology Promotion Center for Smart City Green Construction and Rehabilitation, Chongqing Municipal Education Commission.
Abstract (Originalsprache)
Equivalent thermal calculations describe mean heat transfer, but their accuracy may not extend to local thermal-bridge responses in 3D-printed ribbed walls. We compared the ISO 6946 path-layer method with two-dimensional finite-volume solutions for 2700 dry, steady, insulation-filled periodic cells. Four geometry and conductivity parameters were varied at fixed wall thickness, matrix conductivity, and surface resistances. Numerical benchmarks, mesh checks and ANSYS APDL cross-checks of five selected cases (resistance differences within 0.14%) assessed implementation. Experimental validation was not performed. Resistance error was within 5% for 72.2% of the full grid but for only 6.7% of a 75-case subset selected using literature-reported geometric and conductivity ranges. These proportions characterize the selected domains, not constructed-wall populations. The conductivity contrast at which the resistance error crossed 5% varied with geometry. Resistance errors also changed with wall scale and surface resistance. Sensitivity calculations with air cores used prescribed equivalent resistances without resolving cavity convection or radiation; ISO cavity-geometry compliance was not confirmed. Within the full-grid 5% band, the peak-to-mean heat-flux ratio reached 2.72, and the equivalent model overpredicted minimum internal surface temperature by up to 3.21 K. Global resistance accuracy is therefore not a proxy for local thermal accuracy: conditional error maps can screen resistance, but minimum surface temperature and peak heat flux need explicit-field assessment.
Förderung
- Applied Technology Promotion Center for Smart City Green Construction and Rehabilitation, Chongqing Municipal Education Commission
Zitieren
APA
Hu, X., Liao, Z., & Deng, Z. (2026). Response-Specific Applicability of Equivalent Thermal Models for 3D-Printed Ribbed Wall Envelopes. Buildings, 16(21), 4213. https://doi.org/10.3390/buildings16214213
Vancouver
Hu X, Liao Z, Deng Z. Response-Specific Applicability of Equivalent Thermal Models for 3D-Printed Ribbed Wall Envelopes. Buildings. 2026;16(21):4213. doi:10.3390/buildings16214213
BibTeX
@article{Hu2026,
author = {Hu, Xiaoyi and Liao, Zaiyi and Deng, Zhuo},
title = {Response-Specific Applicability of Equivalent Thermal Models for 3D-Printed Ribbed Wall Envelopes},
journal = {Buildings},
year = {2026},
volume = {16},
number = {21},
pages = {4213},
doi = {10.3390/buildings16214213}
}
EUVIMED